Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1710 | Luft/Wasser | Vaillant Geotherm | 2025 | 129 | 2 | 1275.0 | 3460.0 | 9999 | 2.71 | 561.0 | 1485.0 | 2.65 | 427.0 | 1204.0 | 2.82 | 287.0 | 771.0 | 9999 | 2.69 | |||||||||||||||||||||||||||||||||||||||||||||||||||
1710 | Luft/Wasser | Vaillant Geotherm | 2016 | 129 | 3 | 1843.7 | 4838.2 | 671 | 2.62 | 590.0 | 1460.0 | 2.47 | 394.0 | 1160.0 | 236 | 2.94 | 399.0 | 1110.0 | 225 | 2.78 | 240.0 | 668.0 | 131 | 2.78 | 133.3 | 300.0 | 55 | 2.25 | 87.4 | 140.2 | 24 | 1.60 | ||||||||||||||||||||||||||||||||||||||
1710 | Luft/Wasser | Vaillant Geotherm | 2015 | 129 | 3 | 3532.0 | 9072.0 | 2.57 | 536.0 | 1474.0 | 2.75 | 518.0 | 1373.0 | 2.65 | 405.0 | 1151.0 | 2.84 | 276.0 | 727.0 | 2.63 | 146.0 | 306.0 | 2.10 | 116.0 | 207.0 | 1.78 | 115.0 | 198.0 | 1.72 | 106.0 | 190.0 | 1.79 | 116.0 | 201.0 | 1.73 | 289.0 | 847.0 | 2.93 | 435.0 | 1153.0 | 2.65 | 474.0 | 1245.0 | 2.63 | ||||||||||||||||||||||||||
1710 | Luft/Wasser | Vaillant Geotherm | 2014 | 129 | 4 | 2103.0 | 613.0 | 1.09 | 0 | 0 | 0 | 282.0 | 200.0 | 127.0 | 89.0 | 90.0 | 166.0 | 236.0 | 351.0 | 562.0 | 613.0 | 1.09 |
NR | 1710 |
Username | heisinger |
Einbaujahr der WP | 2013-11-01 |
PLZ des Wohnortes | A-7000 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant Geotherm |
modulierend | |
Leistung (0/35) | 0.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 51 °C |
WW Legionellenschaltung | wöchentlich |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 129 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |