Verbrauchsdaten fuer Anlage Nr. 1720
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2026 | 1465 | 5392 | 3.68 | 503 | 1928 | 3.83 | 379 | 1419 | 3.74 | 357 | 1275 | 3.57 | 225 | 770 | 3.42 | |||||||||||||||||||||||||
| 2025 | 2817 | 10474 | 3.72 | 469 | 1868 | 3.98 | 425 | 1605 | 3.77 | 344 | 1241 | 3.61 | 199 | 684 | 3.45 | 135 | 428 | 3.16 | 52 | 114 | 2.21 | 66 | 175 | 2.65 | 60 | 159 | 2.67 | 114 | 396 | 3.47 | 204 | 759 | 3.72 | 322 | 1346 | 4.18 | 427 | 1699 | 3.98 | |
| 2024 | 2622 | 10102 | 3.85 | 473 | 1853 | 3.91 | 336 | 1264 | 3.76 | 323 | 1195 | 3.70 | 224 | 845 | 3.76 | 78 | 202 | 2.60 | 49 | 108 | 2.21 | 45 | 99 | 2.18 | 41 | 82 | 2.01 | 84 | 304 | 3.63 | 181 | 792 | 4.38 | 332 | 1488 | 4.48 | 456 | 1871 | 4.10 | |
| 2023 | 2487 | 9417 | 3.79 | 410 | 1658 | 4.04 | 364 | 1386 | 3.81 | 319 | 1191 | 3.73 | 258 | 953 | 3.70 | 127 | 400 | 3.15 | 48 | 90 | 1.88 | 43 | 76 | 1.78 | 43 | 83 | 1.93 | 41 | 78 | 1.90 | 131 | 508 | 3.87 | 306 | 1344 | 4.39 | 398 | 1651 | 4.14 | |
| 2022 | 2655 | 9836 | 3.71 | 465 | 1796 | 3.86 | 398 | 1489 | 3.75 | 391 | 1436 | 3.67 | 291 | 1040 | 3.57 | 105 | 291 | 2.79 | 53 | 99 | 1.86 | 47 | 83 | 1.77 | 42 | 76 | 1.82 | 102 | 360 | 3.52 | 117 | 383 | 3.26 | 257 | 1148 | 4.47 | 387 | 1635 | 4.22 | |
| 2021 | 2951 | 11131 | 3.77 | 490 | 1964 | 4.01 | 372 | 1423 | 3.83 | 379 | 1435 | 3.79 | 305 | 1134 | 3.72 | 210 | 744 | 3.55 | 57 | 104 | 1.84 | 52 | 98 | 1.87 | 57 | 130 | 2.29 | 79 | 222 | 2.80 | 210 | 852 | 4.06 | 334 | 1401 | 4.19 | 407 | 1624 | 3.99 | |
| 2020 | 2766 | 10560 | 3.82 | 432 | 1749 | 4.05 | 374 | 1474 | 3.94 | 369 | 1427 | 3.86 | 209 | 731 | 3.50 | 132 | 439 | 3.34 | 123 | 232 | 1.89 | 55 | 106 | 1.94 | 51 | 98 | 1.92 | 85 | 268 | 3.17 | 224 | 953 | 4.26 | 296 | 1305 | 4.40 | 417 | 1778 | 4.26 | |
| 2019 | 3119 | 12067 | 3.87 | 596 | 2329 | 3.91 | 430 | 1628 | 3.79 | 391 | 1466 | 3.75 | 285 | 1050 | 3.69 | 247 | 931 | 3.76 | 56 | 122 | 2.20 | 49 | 97 | 1.96 | 47 | 95 | 2.02 | 77 | 240 | 3.12 | 192 | 818 | 4.25 | 343 | 1556 | 4.53 | 407 | 1735 | 4.26 | |
| 2018 | 2818 | 10705 | 3.80 | 430 | 1675 | 3.90 | 504 | 1940 | 3.85 | 464 | 1754 | 3.78 | 139 | 444 | 3.21 | 76 | 195 | 2.56 | 51 | 100 | 1.97 | 45 | 86 | 1.89 | 46 | 91 | 1.97 | 65 | 182 | 2.78 | 179 | 730 | 4.09 | 353 | 1564 | 4.43 | 466 | 1944 | 4.17 | |
| 2017 | 2822 | 10657 | 3.78 | 565 | 2141 | 3.79 | 396 | 1474 | 3.72 | 296 | 1081 | 3.66 | 242 | 914 | 3.78 | 98 | 263 | 2.70 | 53 | 112 | 2.10 | 52 | 103 | 2.00 | 56 | 130 | 2.34 | 99 | 367 | 3.69 | 166 | 664 | 4.01 | 338 | 1502 | 4.45 | 464 | 1906 | 4.11 | |
| 2016 | 2910 | 11175 | 3.84 | 430 | 1678 | 3.90 | 417 | 1599 | 3.83 | 402 | 1505 | 3.74 | 276 | 1025 | 3.71 | 148 | 511 | 3.44 | 51 | 104 | 2.04 | 43 | 87 | 2.02 | 40 | 77 | 1.91 | 56 | 151 | 2.72 | 233 | 1043 | 4.47 | 351 | 1534 | 4.38 | 462 | 1860 | 4.03 | |
| 2015 | 979 | 4134 | 4.22 | 126 | 544 | 4.31 | 247 | 1081 | 4.38 | 267 | 1127 | 4.23 | 340 | 1382 | 4.07 | |||||||||||||||||||||||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
1720
Username
DJBeatMaster
Gebäude Daten
PLZ
89604
Heizfläche (m²)
130
Wärmeübertragung
FBH
Raumtemperatur (°C)
Lüftung
dezKWLWR
Endenergiebedarf (kWh/m²/anno)
berechnet nach Norm
Wärmepumpe Daten
Hersteller / Typ
Nibe F1245-6
Bauart
Sole/Wasser
Heizleistung (kW) (0/35 2/35)
6.0
Betriebsart Mono/Bi/Tri-valent
Mono
Modulierend
Nein
Einbaudatum
2015-08-06
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
Grabenkollektor
Tiefe (m)
1.8
Fläche (m²)
max. Vorlauftemperatur (°C)
40.0
Spreizung Heizkreise (°K)
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
44
Legionellenschaltung
Nein
Zähler
Stromzähler
extern
Stromzähler erfasst
Kompressor,Steuerung,Pumpen
Wärmemengenzähler
intern
Informationen
Bemerkungen
Links