Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1874 | Luft/Wasser | Buderus WPL 6 ARE | 5.0 | 2024 | 155 | 2 | 1192.0 | 5492.0 | 2162 | 4.61 | 413.0 | 1775.0 | 676 | 4.30 | 237.0 | 1228.0 | 554 | 5.18 | 196.0 | 1058.0 | 508 | 5.40 | 156.0 | 800.0 | 351 | 5.13 | 41.0 | 133.0 | 18 | 3.24 | 57.0 | 224.0 | 47 | 3.93 | 63.0 | 195.0 | 7 | 3.10 | 29.0 | 79.0 | 1 | 2.72 | ||||||||||||||||||||||||||||
1874 | Luft/Wasser | Buderus WPL 6 ARE | 5.0 | 2023 | 155 | 2 | 2043.0 | 9321.0 | 3690 | 4.56 | 292.0 | 1385.0 | 584 | 4.74 | 268.0 | 1216.0 | 511 | 4.54 | 270.0 | 1263.0 | 544 | 4.68 | 179.0 | 908.0 | 416 | 5.07 | 85.0 | 401.0 | 152 | 4.72 | 75.0 | 301.0 | 15 | 4.01 | 54.0 | 165.0 | 2 | 3.06 | 38.0 | 91.0 | 4 | 2.39 | 45.0 | 147.0 | 19 | 3.27 | 128.0 | 703.0 | 305 | 5.49 | 297.0 | 1356.0 | 579 | 4.57 | 312.0 | 1385.0 | 559 | 4.44 | ||||||||||||
1874 | Luft/Wasser | Buderus WPL 6 ARE | 5.0 | 2022 | 155 | 2 | 2107.0 | 9697.0 | 3871 | 4.60 | 323.0 | 1592.0 | 650 | 4.93 | 275.0 | 1385.0 | 569 | 5.04 | 391.0 | 1835.0 | 778 | 4.69 | 65.0 | 320.0 | 136 | 4.92 | 61.0 | 226.0 | 70 | 3.70 | 49.0 | 154.0 | 3.14 | 72.0 | 245.0 | 3.40 | 62.0 | 241.0 | 2 | 3.89 | 73.0 | 357.0 | 357 | 4.89 | 89.0 | 474.0 | 176 | 5.33 | 233.0 | 1180.0 | 495 | 5.06 | 414.0 | 1688.0 | 638 | 4.08 | ||||||||||||||
1874 | Luft/Wasser | Buderus WPL 6 ARE | 5.0 | 2021 | 155 | 2 | 2394.0 | 10554.0 | 4033 | 4.41 | 484.0 | 1924.0 | 700 | 3.98 | 334.0 | 1305.0 | 481 | 3.91 | 287.0 | 1369.0 | 601 | 4.77 | 207.0 | 1035.0 | 460 | 5.00 | 135.0 | 687.0 | 274 | 5.09 | 45.0 | 189.0 | 4.20 | 46.0 | 154.0 | 3.35 | 34.0 | 80.0 | 2.35 | 55.0 | 196.0 | 49 | 3.56 | 124.0 | 686.0 | 295 | 5.53 | 236.0 | 1248.0 | 553 | 5.29 | 407.0 | 1681.0 | 620 | 4.13 | |||||||||||||||
1874 | Luft/Wasser | Buderus WPL 6 ARE | 5.0 | 2020 | 155 | 2 | 1887.0 | 8887.0 | 3163 | 4.71 | 271.0 | 1403.0 | 573 | 5.18 | 260.0 | 1273.0 | 461 | 4.90 | 271.0 | 1261.0 | 480 | 4.65 | 164.0 | 800.0 | 326 | 4.88 | 134.0 | 609.0 | 234 | 4.54 | 62.0 | 249.0 | 10 | 4.02 | 44.0 | 76.0 | 1 | 1.73 | 88.0 | 386.0 | 4.39 | 38.0 | 89.0 | 2.34 | 29.0 | 171.0 | 12 | 5.90 | 207.0 | 1087.0 | 473 | 5.25 | 319.0 | 1483.0 | 593 | 4.65 | ||||||||||||||
1874 | Luft/Wasser | Buderus WPL 6 ARE | 5.0 | 2019 | 155 | 2 | 2163.0 | 10192.0 | 3984 | 4.71 | 435.0 | 1765.0 | 662 | 4.06 | 260.0 | 1234.0 | 527 | 4.75 | 251.0 | 1321.0 | 621 | 5.26 | 140.0 | 682.0 | 293 | 4.87 | 127.0 | 630.0 | 268 | 4.96 | 79.0 | 317.0 | 31 | 4.01 | 55.0 | 274.0 | 3 | 4.98 | 70.0 | 274.0 | 28 | 3.91 | 31.0 | 80.0 | 1 | 2.58 | 152.0 | 794.0 | 317 | 5.22 | 253.0 | 1292.0 | 577 | 5.11 | 310.0 | 1529.0 | 656 | 4.93 | ||||||||||||
1874 | Luft/Wasser | Buderus WPL 6 ARE | 5.0 | 2018 | 155 | 2 | 2337.8 | 9935.7 | 3616 | 4.25 | 352.0 | 1520.0 | 561 | 4.32 | 424.0 | 1613.0 | 613 | 3.80 | 390.8 | 1690.7 | 691 | 4.33 | 119.0 | 631.0 | 265 | 5.30 | 53.0 | 176.0 | 48 | 3.32 | 58.0 | 87.0 | 1.50 | 87.0 | 380.0 | 4.37 | 60.0 | 210.0 | 3.50 | 71.0 | 262.0 | 31 | 3.69 | 164.0 | 689.0 | 278 | 4.20 | 249.0 | 1113.0 | 503 | 4.47 | 310.0 | 1564.0 | 626 | 5.05 | |||||||||||||||
1874 | Luft/Wasser | Buderus WPL 6 ARE | 5.0 | 2017 | 155 | 2 | 2116.0 | 8684.0 | 3063 | 4.10 | 417.0 | 1546.0 | 580 | 3.71 | 313.0 | 1307.0 | 469 | 4.18 | 196.0 | 897.0 | 382 | 4.58 | 195.0 | 827.0 | 336 | 4.24 | 88.0 | 322.0 | 96 | 3.66 | 48.0 | 113.0 | 2.35 | 42.0 | 97.0 | 2.31 | 48.0 | 106.0 | 2.21 | 43.0 | 111.0 | 1 | 2.58 | 114.0 | 530.0 | 64 | 4.65 | 255.0 | 1271.0 | 555 | 4.98 | 357.0 | 1557.0 | 580 | 4.36 | |||||||||||||||
1874 | Luft/Wasser | Buderus WPL 6 ARE | 5.0 | 2016 | 155 | 2 | 216.0 | 911.0 | 295 | 4.22 | 216.0 | 911.0 | 295 | 4.22 |
NR | 1874 |
Username | Arne1 |
Einbaujahr der WP | 2016-10-27 |
PLZ des Wohnortes | 25554 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Buderus WPL 6 ARE |
modulierend | Ja |
Leistung (0/35) | 5.0 kW |
berechneter Primärenergiebedarf | 55.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 52 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 16 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 155 m² |
Lüftung | zenKWL |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | kein Pufferspeicher, keine externe Heizungspumpe, Bypass mit Stellmotor geschlossen im Heizbetrieb |