Verbrauchsdaten fuer Anlage Nr. 1887
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2017 | 4 | 3555 | 10222 | 2.88 | 840 | 2123 | 2.53 | 447 | 1327 | 2.97 | 295 | 893 | 3.03 | 288 | 840 | 2.92 | 152 | 451 | 2.97 | 66 | 120 | 1.82 | 67 | 121 | 1.81 | 73 | 138 | 1.89 | 160 | 522 | 3.26 | 183 | 621 | 3.39 | 404 | 1328 | 3.29 | 580 | 1738 | 3.00 |
| 2016 | 4 | 1012 | 3796 | 3.75 | 875 | 440 | 1319 | 3.00 | 572 | 1602 | 2.80 | |||||||||||||||||||||||||||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
1887
Username
Rabenschwand
Gebäude Daten
PLZ
A-4894
Heizfläche (m²)
148
Wärmeübertragung
FBH
Raumtemperatur (°C)
22.0
Lüftung
Fenster
Endenergiebedarf (kWh/m²/anno)
95.8
berechnet nach Norm
Wärmepumpe Daten
Hersteller / Typ
Hoval belaria srm 8
Bauart
Luft/Wasser
Heizleistung (kW) (0/35 2/35)
5.8
Betriebsart Mono/Bi/Tri-valent
Bi
Modulierend
Einbaudatum
2015-11-15
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
Luft
Tiefe (m)
Fläche (m²)
max. Vorlauftemperatur (°C)
35.0
Spreizung Heizkreise (°K)
5.0
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
43
Legionellenschaltung
Nein
Zähler
Stromzähler
Stromzähler erfasst
Wärmemengenzähler
Informationen
Bemerkungen
Aufstellung Außeneinheit Norden gegen Hang. 2.5m von Haus entfernt.
Kalte Ausblasluft rinnt eventuell zu WP zurück.
Links