| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 1944 | Luft/Wasser | Viessmann - Vitocal 200-S | 7.0 | 2017 | 165 | 3 | 2223.0 | 7099.8 | 3.19 | 712.0 | 2024.0 | 2.84 | 399.0 | 1329.0 | 3.33 | 260.0 | 904.1 | 3.48 | 246.0 | 838.7 | 3.41 | 122.0 | 412.0 | 3.38 | 55.0 | 132.0 | 2.40 | 57.0 | 138.0 | 2.42 | 58.0 | 147.0 | 2.53 | 132.0 | 506.0 | 3.83 | 182.0 | 669.0 | 3.68 | |||||||||||||||||||||||||||||||
| 1944 | Luft/Wasser | Viessmann - Vitocal 200-S | 7.0 | 2016 | 165 | 2 | 3062.9 | 10110.0 | 3.30 | 489.9 | 1568.0 | 3.20 | 418.0 | 1414.0 | 3.38 | 387.0 | 1260.0 | 3.26 | 233.0 | 745.0 | 3.20 | 129.0 | 431.0 | 3.34 | 52.0 | 125.0 | 2.40 | 50.0 | 121.0 | 2.42 | 56.0 | 134.0 | 2.39 | 82.0 | 266.0 | 3.24 | 269.0 | 1005.0 | 3.74 | 403.0 | 1428.0 | 3.54 | 494.0 | 1613.0 | 3.27 | |||||||||||||||||||||||||
| 1944 | Luft/Wasser | Viessmann - Vitocal 200-S | 7.0 | 2015 | 165 | 2 | 3172.0 | 9305.0 | 2.93 | 565.0 | 1946.0 | 3.44 | 554.0 | 1385.0 | 2.50 | 372.0 | 1128.0 | 3.03 | 239.0 | 475.0 | 1.99 | 143.0 | 390.0 | 2.73 | 60.0 | 158.0 | 2.63 | 54.0 | 127.0 | 2.35 | 55.0 | 125.0 | 2.27 | 121.0 | 347.0 | 2.87 | 302.0 | 947.0 | 3.14 | 332.0 | 1006.0 | 3.03 | 375.0 | 1271.0 | 3.39 | |||||||||||||||||||||||||
| 1944 | Luft/Wasser | Viessmann - Vitocal 200-S | 7.0 | 2014 | 165 | 2 | 331.0 | 1074.0 | 3.24 | 331.0 | 1074.0 | 3.24 |
| NR | 1944 |
| Username | Konni |
| Einbaujahr der WP | 2014-03-01 |
| PLZ des Wohnortes | 87665 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Viessmann - Vitocal 200-S |
| modulierend | |
| Leistung (0/35) | 7.0 kW |
| berechneter Primärenergiebedarf | 28.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | wöchentlich |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 3000 Watt gem. |
| elektr. Verbrauch HP gem./DB | 35 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | > erfasst: |
| WMZ | |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 35.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 165 m² |
| Lüftung | zenKWLWR |
| Personen | 3 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |