Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
196 | Sole/Wasser | Tecalor TTF 5 | 5.8 | 2016 | 140 | 4 | 1044.0 | 5167.0* | 733 | 4.95 | 310.0 | 1314.0 | 217 | 5.14 | 384.0 | 1373.0 | 237 | 4.30 | 350.0 | 1640.0 | 279 | 5.49 | ||||||||||||||||||||||||||||||||||||||||||||||||
196 | Sole/Wasser | Tecalor TTF 5 | 5.8 | 2015 | 140 | 4 | 3845.0 | 13751.0* | 2743 | 3.58 | 535.0 | 1644.0 | 351 | 3.60 | 568.0 | 1677.0 | 367 | 3.45 | 467.0 | 1641.0 | 381 | 4.11 | 324.0 | 1422.0 | 350 | 5.25 | 195.0 | 939.0 | 254 | 6.25 | 118.0 | 405.0 | 132 | 5.81 | 40.0 | 155.0 | 1 | 10.88 | 86.0 | 38.0 | 107 | 3.70 | 213.0 | 40.0 | 48 | 1.50 | 362.0 | 502.0 | 157 | 2.16 | 432.0 | 955.0 | 294 | 2.86 | 505.0 | 973.0 | 301 | 2.48 | ||||||||||||
196 | Sole/Wasser | Tecalor TTF 5 | 5.8 | 2012 | 140 | 4 | 3063.0 | 12768.0* | 1888 | 4.17 | 508.0 | 1884.0 | 337 | 4.26 | 560.0 | 1900.0 | 364 | 3.89 | 338.0 | 967.0 | 201 | 3.69 | 267.0 | 976.0 | 194 | 4.70 | 141.0 | 367.0 | 92 | 4.59 | 95.0 | 182.0 | 1 | 4.86 | 46.0 | 39.0 | 51 | 6.93 | 46.0 | 40.0 | 52 | 6.96 | 91.0 | 217.0 | 57 | 5.46 | 194.0 | 609.0 | 115 | 4.58 | 353.0 | 1346.0 | 241 | 4.61 | 424.0 | 881.0 | 183 | 2.74 | ||||||||||||
196 | Sole/Wasser | Tecalor TTF 5 | 5.8 | 2011 | 140 | 4 | 1885.0 | 8550.0* | 1736 | 4.54 | 2478.0 | 447 | 558.0 | 110 | 354.0 | 1106.0 | 223 | 3.92 | 193.0 | 547.0 | 122 | 4.28 | 126.0 | 305.0 | 78 | 4.64 | 90.0 | 183.0 | 52 | 5.14 | 84.0 | 141.0 | 47 | 5.01 | 72.0 | 74.0 | 40 | 4.92 | 104.0 | 249.0 | 60 | 5.09 | 196.0 | 667.0 | 123 | 4.83 | 293.0 | 1078.0 | 188 | 4.63 | 373.0 | 1400.0 | 246 | 4.50 | ||||||||||||||||
196 | Sole/Wasser | Tecalor TTF 5 | 5.8 | 2010 | 140 | 4 | 2361.0 | 11048.0* | 1496 | 4.68 | 584.0 | 2147.0 | 369 | 4.16 | 452.0 | 1707.0 | 290 | 4.40 | 381.0 | 1704.0 | 249 | 5.21 | 250.0 | 731.0 | 168 | 4.04 | 197.0 | 630.0 | 125 | 4.62 | 74.0 | 71.0 | 40 | 4.74 | 52.0 | 5.0 | 26 | 5.48 | 52.0 | 41.0 | 27 | 6.17 | 108.0 | 372.0 | 68 | 6.04 | 211.0 | 840.0 | 134 | 5.31 | ||||||||||||||||||||
196 | Sole/Wasser | Tecalor TTF 5 | 5.8 | 2009 | 140 | 4 | 1055.7 | 4105.0* | 434 | 4.89 | 79.3 | 60.2 | 76.0 | 164.0 | 609.0 | 5.42 | 232.4 | 903.0 | 147 | 5.09 | 443.8 | 1753.0 | 287 | 4.58 |
NR | 196 |
Username | burgerg |
Einbaujahr der WP | 2009-06-15 |
PLZ des Wohnortes | 52511 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Tecalor TTF 5 |
modulierend | |
Leistung (0/35) | 5.8 kW |
berechneter Primärenergiebedarf | 57.7 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | sonstige |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 4.5 |
Heizflaeche | 140 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | 14 Stück Erdwärmekörbe je 4m Lang |