Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1978 | Luft/Wasser | Novelan LAD 9 CSD | 5.0 | 2020 | 144 | 4 | 2186.4 | 7834.3 | 1241 | 3.58 | 325.5 | 1169.4 | 203 | 3.59 | 289.6 | 1082.6 | 179 | 3.74 | 296.3 | 1111.1 | 181 | 3.75 | 130.0 | 449.6 | 66 | 3.46 | 99.4 | 337.5 | 46 | 3.40 | 78.9 | 275.5 | 34 | 3.49 | 81.7 | 284.6 | 36 | 3.48 | 67.0 | 221.9 | 26 | 3.31 | 83.2 | 277.8 | 38 | 3.34 | 144.0 | 531.7 | 76 | 3.69 | 262.4 | 920.4 | 155 | 3.51 | 328.4 | 1172.2 | 201 | 3.57 | ||||||||||||
1978 | Luft/Wasser | Novelan LAD 9 CSD | 5.0 | 2019 | 144 | 4 | 2513.9 | 8528.8 | 1492 | 3.39 | 429.8 | 1519.4 | 280 | 3.54 | 361.5 | 1022.1 | 229 | 2.83 | 300.0 | 923.0 | 182 | 3.08 | 159.0 | 506.0 | 89 | 3.18 | 169.0 | 621.0 | 94 | 3.67 | 78.0 | 283.0 | 34 | 3.63 | 73.0 | 245.0 | 31 | 3.36 | 74.0 | 257.0 | 32 | 3.47 | 73.9 | 238.8 | 32 | 3.23 | 150.7 | 530.6 | 83 | 3.52 | 303.4 | 1109.6 | 189 | 3.66 | 341.6 | 1273.3 | 217 | 3.73 | ||||||||||||
1978 | Luft/Wasser | Novelan LAD 9 CSD | 5.0 | 2018 | 144 | 3 | 2895.1 | 9234.4 | 967 | 3.19 | 375.0 | 1301.0 | 129 | 3.47 | 491.0 | 1565.0 | 183 | 3.19 | 407.0 | 1273.3 | 142 | 3.13 | 194.0 | 520.8 | 56 | 2.68 | 130.0 | 422.0 | 34 | 3.25 | 103.0 | 324.0 | 24 | 3.15 | 91.0 | 283.4 | 21 | 3.11 | 117.0 | 365.8 | 26 | 3.13 | 115.0 | 374.0 | 32 | 3.25 | 182.0 | 612.1 | 54 | 3.36 | 325.0 | 1042.8 | 109 | 3.21 | 365.1 | 1150.2 | 157 | 3.15 | ||||||||||||
1978 | Luft/Wasser | Novelan LAD 9 CSD | 5.0 | 2017 | 144 | 3 | 3059.5 | 9669.3 | 959 | 3.16 | 681.0 | 2017.0 | 238 | 2.96 | 391.0 | 1362.0 | 137 | 3.48 | 304.0 | 1029.0 | 102 | 3.38 | 270.0 | 950.0 | 95 | 3.52 | 155.0 | 491.0 | 41 | 3.17 | 96.0 | 315.0 | 23 | 3.28 | 81.0 | 278.0 | 20 | 3.43 | 89.5 | 310.8 | 23 | 3.47 | 110.0 | 349.3 | 28 | 3.18 | 182.0 | 648.2 | 53 | 3.56 | 306.0 | 812.0 | 108 | 2.65 | 394.0 | 1107.0 | 91 | 2.81 |
NR | 1978 |
Username | bart2005 |
Einbaujahr der WP | 2016-08-01 |
PLZ des Wohnortes | 53797 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Novelan LAD 9 CSD |
modulierend | |
Leistung (0/35) | 5.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 144 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Neubau 2016 Ende 2018 Umbau auf Novelan LAD 5 CSD |