Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1998 | Sole/Wasser | Thermia Diplomat 12 | 10.7 | 2019 | 160 | 3 | 1495.6 | 968.0 | 382 | 0.65 | 1495.6 | 968.0 | 382 | 0.65 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1998 | Sole/Wasser | Thermia Diplomat 12 | 10.7 | 2018 | 160 | 3 | 7455.1 | 6156.4 | 1877 | 0.83 | 1318.0 | 980.6 | 336 | 0.74 | 1501.0 | 887.9 | 386 | 0.59 | 1319.0 | 1023.5 | 344 | 0.78 | 297.2 | 593.0 | 70 | 2.00 | 68.1 | 157.0 | 14 | 2.31 | 7.9 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 135.7 | 2.0 | 30 | 0.01 | 565.1 | 847.7 | 135 | 1.50 | 975.2 | 788.5 | 237 | 0.81 | 1267.9 | 876.2 | 325 | 0.69 | |||||||||||||||
1998 | Sole/Wasser | Thermia Diplomat 12 | 10.7 | 2017 | 160 | 3 | 7476.9 | 3226.7 | 1820 | 1.09 | 1721.0 | 350 | 1132.0 | 305 | 799.0 | 205 | 631.0 | 160 | 205.0 | 50 | 9.6 | 2 | 16.1 | 3 | 10.1 | 2 | 247.4 | 359.4 | 56 | 1.45 | 461.0 | 880.3 | 110 | 1.91 | 961.5 | 948.0 | 247 | 0.99 | 1283.2 | 1039.0 | 330 | 0.81 | ||||||||||||||||||||||||||||
1998 | Sole/Wasser | Thermia Diplomat 12 | 10.7 | 2016 | 160 | 3 | 7657.0 | 2140 | 1553.0 | 421 | 1105.0 | 303 | 1013.0 | 276 | 609.0 | 159 | 178.0 | 41 | 14.0 | 3 | 6.0 | 1 | 13.0 | 2 | 75.0 | 15 | 578.0 | 148 | 903.0 | 305 | 1610.0 | 466 | ||||||||||||||||||||||||||||||||||||||
1998 | Sole/Wasser | Thermia Diplomat 12 | 10.7 | 2015 | 160 | 3 | 6493.0 | 1659 | 1063.0 | 266 | 1144.0 | 265 | 945.0 | 259 | 526.0 | 137 | 43.0 | 11 | 42.0 | 10 | 5.0 | 1 | 4.0 | 232.0 | 52 | 637.0 | 165 | 796.0 | 208 | 1056.0 | 285 | |||||||||||||||||||||||||||||||||||||||
1998 | Sole/Wasser | Thermia Diplomat 12 | 10.7 | 2013 | 160 | 3 | 8649.0 | 1593.0 | 1435.0 | 1486.0 | 608.0 | 249.0 | 119.0 | 9.0 | 9.0 | 234.0 | 441.0 | 1220.0 | 1246.0 |
NR | 1998 |
Username | thermo |
Einbaujahr | 2009-06-01 |
PLZ des Wohnortes | 04277 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Thermia Diplomat 12 |
Leistung (0/35) | 10.7 kW |
berechneter Primärenergiebedarf | 66.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 3 Erdbohrungen a |
Tiefe | 65.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 2470 Watt DB |
elektr. Verbrauch HP gem./DB | 120 Watt |
elektr. Verbrauch WQ P gem./DB | 395 Watt |
Mittlere Raumtemp. | 22 °C |
Mittlere Wärmequellentemperatur | 5.0 °C |
Heizung max. Vorlauf Temp. | 45.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 160 m² |
Lüftung | Fenster |
Personen | 5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | keine |
Bemerkungen | # Wärmepumpe mit Solaranlage, 4 x Pumpen (Sole, Heizung, FBH, Solar) FBH, Plattenheizkörper, Radiatoren |