Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2052 | Sole/Wasser | Nibe F1255-6 | 3.3 | 2024 | 145 | 2 | 1324.0 | 7956.0 | 6.01 | 1324.0 | 7956.0 | 6.01 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2052 | Sole/Wasser | Nibe F1255-6 | 3.3 | 2023 | 145 | 2 | 1313.0 | 8035.1 | 6.12 | 207.1 | 1289.0 | 6.22 | 178.4 | 1105.2 | 6.20 | 184.5 | 1117.4 | 6.06 | 126.3 | 744.7 | 5.90 | 49.6 | 221.1 | 4.46 | 28.9 | 255.8 | 8.85 | 33.7 | 182.1 | 5.40 | 27.6 | 193.5 | 7.01 | 23.7 | 143.7 | 6.06 | 78.9 | 450.0 | 5.70 | 160.7 | 1014.3 | 6.31 | 213.6 | 1318.3 | 6.17 | |||||||||||||||||||||||||
2052 | Sole/Wasser | Nibe F1255-6 | 3.3 | 2022 | 145 | 2 | 1291.0 | 7806.0 | 6.05 | 218.4 | 1351.8 | 6.19 | 192.9 | 1186.3 | 6.15 | 157.9 | 913.7 | 5.79 | 119.6 | 690.2 | 5.77 | 39.9 | 151.0 | 3.78 | 22.1 | 55.1 | 2.49 | 31.1 | 253.0 | 8.14 | 40.7 | 409.0 | 10.05 | 45.3 | 208.7 | 4.61 | 60.1 | 310.2 | 5.16 | 141.0 | 885.7 | 6.28 | 222.0 | 1391.3 | 6.27 | |||||||||||||||||||||||||
2052 | Sole/Wasser | Nibe F1255-6 | 3.3 | 2021 | 145 | 2 | 1543.6 | 9149.0 | 5.93 | 251.0 | 1566.0 | 6.24 | 213.0 | 1254.0 | 5.89 | 189.4 | 1130.2 | 5.97 | 157.6 | 910.5 | 5.78 | 101.7 | 525.0 | 5.16 | 39.9 | 320.7 | 8.04 | 29.1 | 188.7 | 6.48 | 31.9 | 121.9 | 3.82 | 27.5 | 70.3 | 2.56 | 113.0 | 621.0 | 5.50 | 163.3 | 1032.3 | 6.32 | 226.2 | 1408.4 | 6.23 | |||||||||||||||||||||||||
2052 | Sole/Wasser | Nibe F1255-6 | 3.3 | 2020 | 145 | 2 | 1439.3 | 8248.2 | 5.73 | 224.0 | 1395.0 | 6.23 | 203.4 | 1253.5 | 6.16 | 189.3 | 1121.5 | 5.92 | 136.0 | 407.0 | 2.99 | 68.0 | 344.0 | 5.06 | 45.6 | 230.0 | 5.04 | 34.0 | 122.0 | 3.59 | 39.0 | 411.0 | 10.54 | 44.0 | 122.1 | 2.78 | 99.0 | 597.0 | 6.03 | 150.0 | 935.1 | 6.23 | 207.0 | 1310.0 | 6.33 | |||||||||||||||||||||||||
2052 | Sole/Wasser | Nibe F1255-6 | 3.3 | 2019 | 145 | 2 | 1512.0 | 8781.4 | 2442 | 5.81 | 256.0 | 1575.0 | 744 | 6.15 | 195.5 | 1154.4 | 528 | 5.90 | 188.1 | 1137.8 | 623 | 6.05 | 116.4 | 598.3 | 280 | 5.14 | 92.0 | 420.6 | 191 | 4.57 | 29.0 | 127.7 | 19 | 4.40 | 46.0 | 276.7 | 28 | 6.02 | 47.0 | 248.0 | 29 | 5.28 | 38.0 | 134.9 | 3.55 | 102.0 | 557.0 | 5.46 | 189.0 | 1201.0 | 6.35 | 213.0 | 1350.0 | 6.34 | ||||||||||||||||
2052 | Sole/Wasser | Nibe F1255-6 | 3.3 | 2018 | 145 | 2 | 1573.0 | 8490.8 | 3092 | 5.40 | 237.0 | 1482.0 | 719 | 6.25 | 258.0 | 1556.0 | 674 | 6.03 | 253.0 | 1519.0 | 6.00 | 98.0 | 410.0 | 4.18 | 64.0 | 176.0 | 62 | 2.75 | 45.0 | 87.8 | 28 | 1.95 | 49.6 | 87.0 | 26 | 1.75 | 30.4 | 56.7 | 19 | 1.87 | 54.0 | 159.6 | 61 | 2.96 | 95.0 | 481.0 | 215 | 5.06 | 174.0 | 1104.7 | 563 | 6.35 | 215.0 | 1371.0 | 725 | 6.38 | ||||||||||||||
2052 | Sole/Wasser | Nibe F1255-6 | 3.3 | 2017 | 145 | 2 | 1112.0 | 5559.4 | 2302 | 5.00 | 360.0 | 1521.0 | 410 | 4.23 | 55.0 | 71.0 | 25 | 1.29 | 49.0 | 100.4 | 2.05 | 69.0 | 290.0 | 132 | 4.20 | 115.0 | 654.0 | 327 | 5.69 | 196.0 | 1246.0 | 664 | 6.36 | 268.0 | 1677.0 | 744 | 6.26 |
NR | 2052 |
Username | Becker |
Einbaujahr der WP | 2017-05-09 |
PLZ des Wohnortes | 49451 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F1255-6 |
modulierend | Ja |
Leistung (0/35) | 3.3 kW |
berechneter Primärenergiebedarf | 17.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 90.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 240 Watt gem. |
elektr. Verbrauch HP gem./DB | 8 Watt |
elektr. Verbrauch WQ P gem./DB | 10 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 5.0 °C |
Heizung max. Vorlauf Temp. | 27.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 145 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Nein |
Bemerkungen | ab 2019 addiere ich in den Sommermonate die passive Kühlung zur Wärmemenge dazu. |