Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2065 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2024 | 160 | 1140.0 | 4700.0 | 4.12 | 865.0 | 3800.0 | 4.39 | 155.0 | 600.0 | 3.87 | 65.0 | 150.0 | 2.31 | 55.0 | 150.0 | 2.73 | ||||||||||||||||||||||||||||||||||||||||||||||||||
2065 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2023 | 160 | 3 | 1510.0 | 5680.0 | 3.76 | 345.0 | 1500.0 | 4.35 | 365.0 | 1400.0 | 3.84 | 265.0 | 1100.0 | 4.15 | 145.0 | 1000.0 | 6.90 | 165.0 | 300.0 | 1.82 | 75.0 | 130.0 | 1.73 | 75.0 | 130.0 | 1.73 | 75.0 | 120.0 | 1.60 | |||||||||||||||||||||||||||||||||||||
2065 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2022 | 160 | 3 | 2410.0 | 9200.0 | 3.82 | 335.0 | 1400.0 | 4.18 | 295.0 | 1400.0 | 4.75 | 345.0 | 1200.0 | 3.48 | 185.0 | 900.0 | 4.86 | 135.0 | 300.0 | 2.22 | 95.0 | 200.0 | 2.11 | 45.0 | 150.0 | 3.33 | 75.0 | 250.0 | 3.33 | 85.0 | 200.0 | 2.35 | 85.0 | 300.0 | 3.53 | 265.0 | 1300.0 | 4.91 | 465.0 | 1600.0 | 3.44 | |||||||||||||||||||||||||
2065 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2021 | 160 | 3 | 2710.0 | 11000.0 | 4.06 | 465.0 | 1800.0 | 3.87 | 515.0 | 1600.0 | 3.11 | 345.0 | 1500.0 | 4.35 | 1385.0 | 6100.0 | 4.40 | |||||||||||||||||||||||||||||||||||||||||||||||||
2065 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2020 | 160 | 3 | 2380.0 | 10100.0 | 4.24 | 365.0 | 1500.0 | 4.11 | 325.0 | 1500.0 | 4.62 | 405.0 | 1200.0 | 2.96 | 215.0 | 800.0 | 3.72 | 125.0 | 500.0 | 4.00 | 95.0 | 400.0 | 4.21 | 85.0 | 400.0 | 4.71 | 55.0 | 140.0 | 2.55 | 45.0 | 160.0 | 3.56 | 115.0 | 800.0 | 6.96 | 215.0 | 1200.0 | 5.58 | 335.0 | 1500.0 | 4.48 | |||||||||||||||||||||||||
2065 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2019 | 160 | 3 | 2430.0 | 10400.0 | 4.28 | 459.0 | 1900.0 | 4.14 | 253.0 | 1300.0 | 5.14 | 410.0 | 1400.0 | 3.41 | 153.0 | 700.0 | 4.58 | 147.0 | 700.0 | 4.76 | 36.0 | 101.0 | 2.81 | 36.0 | 199.0 | 5.53 | 26.0 | 100.0 | 3.85 | 155.0 | 200.0 | 1.29 | 155.0 | 800.0 | 5.16 | 235.0 | 1300.0 | 5.53 | 365.0 | 1700.0 | 4.66 | |||||||||||||||||||||||||
2065 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2018 | 160 | 2 | 3107.0 | 11402.0 | 3.67 | 475.0 | 2169.0 | 4.57 | 750.0 | 1857.0 | 2.48 | 578.0 | 1976.0 | 3.42 | 158.0 | 643.0 | 4.07 | 59.0 | 400.0 | 6.78 | 51.0 | 150.0 | 2.94 | 38.0 | 131.0 | 3.45 | 35.0 | 128.0 | 3.66 | 105.0 | 248.0 | 2.36 | 149.0 | 800.0 | 5.37 | 351.0 | 1500.0 | 4.27 | 358.0 | 1400.0 | 3.91 | |||||||||||||||||||||||||
2065 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2017 | 160 | 2 | 1468.0 | 6975.0 | 4.75 | 312.0 | 1625.0 | 5.21 | 90.0 | 550.0 | 6.11 | 151.0 | 800.0 | 5.30 | 418.0 | 1940.0 | 4.64 | 497.0 | 2060.0 | 4.14 |
NR | 2065 |
Username | ares83 |
Einbaujahr der WP | 2017-07-21 |
PLZ des Wohnortes | 27726 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Tecalor THZ504 |
modulierend | Ja |
Leistung (0/35) | 10.0 kW |
berechneter Primärenergiebedarf | 26.7 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 43 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 33.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 160 m² |
Lüftung | zenKWL |
Personen | 2,5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Februar 2018, 5 Tage Notbetrieb, 250kWh Werte für 2021 im Dezember zusammngefasst |