Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2084 | Sole/Wasser | Junkers STE 80 - 1 | 7.5 | 2021 | 170 | 689.6 | 2905.3 | 363 | 4.21 | 161.0 | 639.0 | 78 | 3.97 | 258.4 | 1103.0 | 139 | 4.27 | 270.2 | 1163.3 | 146 | 4.31 | |||||||||||||||||||||||||||||||||||||||||||||||||
2084 | Sole/Wasser | Junkers STE 80 - 1 | 7.5 | 2020 | 170 | 1725.0 | 6596.2 | 804 | 3.82 | 243.0 | 1017.7 | 126 | 4.19 | 235.8 | 990.8 | 123 | 4.20 | 222.6 | 885.0 | 111 | 3.98 | 106.6 | 359.7 | 43 | 3.37 | 93.4 | 330.0 | 37 | 3.53 | 108.8 | 342.1 | 44 | 3.14 | 82.4 | 273.4 | 32 | 3.32 | 89.0 | 289.8 | 35 | 3.26 | 79.8 | 255.1 | 30 | 3.20 | 127.8 | 478.0 | 57 | 3.74 | 158.6 | 636.5 | 77 | 4.01 | 177.2 | 738.1 | 89 | 4.17 | |||||||||||||
2084 | Sole/Wasser | Junkers STE 80 - 1 | 7.5 | 2019 | 170 | 1727.0 | 6806.2 | 829 | 3.94 | 236.6 | 1060.0 | 131 | 4.48 | 218.0 | 955.9 | 119 | 4.38 | 180.4 | 773.0 | 94 | 4.28 | 82.4 | 267.0 | 32 | 3.24 | 73.6 | 237.0 | 28 | 3.22 | 64.8 | 198.3 | 24 | 3.06 | 49.4 | 148.6 | 17 | 3.01 | 71.4 | 226.3 | 27 | 3.17 | 116.2 | 386.0 | 46 | 3.32 | 133.0 | 447.0 | 54 | 3.36 | 223.2 | 918.1 | 111 | 4.11 | 278.0 | 1189.0 | 146 | 4.28 | |||||||||||||
2084 | Sole/Wasser | Junkers STE 80 - 1 | 7.5 | 2018 | 170 | 1330.8 | 5154.9 | 620 | 3.87 | 226.0 | 979.0 | 120 | 4.33 | 191.0 | 798.0 | 98 | 4.18 | 193.0 | 814.0 | 98 | 4.22 | 80.0 | 258.0 | 31 | 3.23 | 75.8 | 247.7 | 29 | 3.27 | 53.8 | 165.3 | 19 | 3.07 | 68.0 | 219.2 | 25 | 3.22 | 69.2 | 223.0 | 26 | 3.22 | 43.0 | 137.7 | 16 | 3.20 | 43.0 | 133.0 | 16 | 3.09 | 124.0 | 498.0 | 60 | 4.02 | 164.0 | 682.0 | 82 | 4.16 | |||||||||||||
2084 | Sole/Wasser | Junkers STE 80 - 1 | 7.5 | 2017 | 170 | 649.4 | 2855.0 | 343 | 4.40 | 105.0 | 405.0 | 48 | 3.86 | 252.0 | 1153.0 | 137 | 4.58 | 292.4 | 1297.0 | 158 | 4.44 |
NR | 2084 |
Username | Iffi |
Einbaujahr der WP | 2017-05-01 |
PLZ des Wohnortes | 45711 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Junkers STE 80 - 1 |
modulierend | Nein |
Leistung (0/35) | 7.5 kW |
berechneter Primärenergiebedarf | 30.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 130.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1630 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 38.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 170 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Seit Mitte 11/2017 Unterstützung durch einen Kaminofen (3-9 KW) - durch offene Bauweise Erwärmung des kompletten Gebäudes. WW-Zirkulation seit 09/2018 deaktiviert. |