Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2087 | Luft/Wasser | Vaillant arotherm VWL 85/3 | 4.6 | 2020 | 170 | 2 | 1031.0 | 4557.0 | 2925 | 4.42 | 278.0 | 1265.1 | 730 | 4.55 | 302.0 | 1461.0 | 729 | 4.84 | 272.0 | 1127.0 | 723 | 4.14 | 179.0 | 703.9 | 743 | 3.93 | ||||||||||||||||||||||||||||||||||||||||||||
2087 | Luft/Wasser | Vaillant arotherm VWL 85/3 | 4.6 | 2019 | 170 | 2 | 2526.4 | 10479.6 | 8770 | 4.15 | 409.0 | 1590.0 | 756 | 3.89 | 287.7 | 1263.6 | 655 | 4.39 | 290.0 | 1318.2 | 744 | 4.55 | 223.0 | 854.9 | 722 | 3.83 | 184.0 | 694.0 | 746 | 3.77 | 104.0 | 510.9 | 722 | 4.91 | 122.4 | 528.1 | 746 | 4.31 | 89.6 | 331.9 | 767 | 3.70 | 70.6 | 278.9 | 705 | 3.95 | 177.3 | 678.2 | 739 | 3.83 | 271.3 | 1164.2 | 723 | 4.29 | 297.5 | 1266.7 | 745 | 4.26 | ||||||||||||
2087 | Luft/Wasser | Vaillant arotherm VWL 85/3 | 4.6 | 2018 | 170 | 2 | 2936.4 | 11129.5 | 8733 | 3.79 | 441.0 | 1613.7 | 707 | 3.66 | 525.0 | 1642.5 | 676 | 3.13 | 430.2 | 1505.6 | 743 | 3.50 | 160.7 | 545.4 | 738 | 3.39 | 105.6 | 498.6 | 718 | 4.72 | 101.7 | 459.1 | 722 | 4.51 | 154.6 | 790.3 | 744 | 5.11 | 92.5 | 401.6 | 747 | 4.34 | 77.1 | 257.7 | 721 | 3.34 | 179.0 | 688.0 | 748 | 3.84 | 319.0 | 1263.0 | 721 | 3.96 | 350.0 | 1464.0 | 748 | 4.18 | ||||||||||||
2087 | Luft/Wasser | Vaillant arotherm VWL 85/3 | 4.6 | 2017 | 170 | 2 | 1103.0 | 4392.7 | 784 | 3.98 | 313.0 | 1279.9 | 4.09 | 400.0 | 1622.8 | 4.06 | 390.0 | 1490.0 | 784 | 3.82 |
NR | 2087 |
Username | koesada |
Einbaujahr der WP | 2017-09-27 |
PLZ des Wohnortes | 25474 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant arotherm VWL 85/3 |
modulierend | Ja |
Leistung (0/35) | 4.6 kW |
berechneter Primärenergiebedarf | 29.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 170 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | KFW55 Q"h 39.28kWh/m²/a Nutzfläche 203.2m²(Boden+Wände) WMZ nach Vailant berechnet: GesamtErtrag = Stromverbrauch + Ertrag vom Display Heizkurche 0,1 WW+HZ Pumpenleistung: 250mbar |