Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2092 | Sole/Wasser | Nibe F1155-6 | 3.3 | 2024 | 220 | 5 | 2838.0 | 13241.0 | 4.67 | 620.0 | 2759.0 | 4.45 | 437.0 | 2006.0 | 4.59 | 408.0 | 1884.0 | 4.62 | 327.0 | 1519.0 | 4.65 | 430.0 | 1518.0 | 3.53 | 252.0 | 1553.0 | 6.16 | 364.0 | 2002.0 | 5.50 | ||||||||||||||||||||||||||||||||||||||||
2092 | Sole/Wasser | Nibe F1155-6 | 3.3 | 2023 | 220 | 4 | 3396.0 | 15561.0 | 4.58 | 540.0 | 2454.0 | 4.54 | 535.0 | 2371.0 | 4.43 | 421.0 | 1901.0 | 4.52 | 383.0 | 1790.0 | 4.67 | 171.0 | 715.0 | 4.18 | 277.0 | 801.0 | 2.89 | 189.0 | 1084.0 | 5.74 | 383.0 | 2100.0 | 5.48 | 497.0 | 2345.0 | 4.72 | ||||||||||||||||||||||||||||||||||
2092 | Sole/Wasser | Nibe F1155-6 | 3.3 | 2022 | 220 | 4 | 3725.0 | 16661.0 | 4.47 | 683.0 | 2933.0 | 4.29 | 464.0 | 1991.0 | 4.29 | 581.0 | 2496.0 | 4.30 | 424.0 | 1873.0 | 4.42 | 135.0 | 480.0 | 3.56 | 532.0 | 2380.0 | 4.47 | 365.0 | 2016.0 | 5.52 | 541.0 | 2492.0 | 4.61 | |||||||||||||||||||||||||||||||||||||
2092 | Sole/Wasser | Nibe F1155-6 | 3.3 | 2021 | 220 | 4 | 4283.0 | 19674.0 | 4.59 | 649.0 | 3005.0 | 4.63 | 566.0 | 2525.0 | 4.46 | 517.0 | 2338.0 | 4.52 | 494.0 | 2227.0 | 4.51 | 327.0 | 1477.0 | 4.52 | 55.0 | 161.0 | 2.93 | 63.0 | 216.0 | 3.43 | 55.0 | 161.0 | 2.93 | 93.0 | 387.0 | 4.16 | 324.0 | 1927.0 | 5.95 | 476.0 | 2337.0 | 4.91 | 664.0 | 2913.0 | 4.39 | |||||||||||||||||||||||||
2092 | Sole/Wasser | Nibe F1155-6 | 3.3 | 2020 | 220 | 4 | 3514.0 | 16787.0 | 5682 | 4.78 | 581.0 | 2592.0 | 759 | 4.46 | 489.0 | 2266.0 | 759 | 4.63 | 462.0 | 2229.0 | 717 | 4.82 | 262.0 | 1209.0 | 466 | 4.61 | 188.0 | 907.0 | 359 | 4.82 | 76.0 | 226.0 | 60 | 2.97 | 76.0 | 226.0 | 118 | 2.97 | 41.0 | 138.0 | 66 | 3.37 | 94.0 | 466.0 | 203 | 4.96 | 271.0 | 1610.0 | 693 | 5.94 | 394.0 | 2153.0 | 748 | 5.46 | 580.0 | 2765.0 | 734 | 4.77 | ||||||||||||
2092 | Sole/Wasser | Nibe F1155-6 | 3.3 | 2019 | 220 | 4 | 3222.0 | 15258.0 | 5119 | 4.74 | 652.0 | 2872.0 | 731 | 4.40 | 486.0 | 2162.0 | 683 | 4.45 | 395.0 | 1865.0 | 709 | 4.72 | 254.0 | 1152.0 | 472 | 4.54 | 215.0 | 1088.0 | 402 | 5.06 | 66.0 | 200.0 | 51 | 3.03 | 53.0 | 164.0 | 41 | 3.09 | 57.0 | 158.0 | 41 | 2.77 | 80.0 | 329.0 | 95 | 4.11 | 160.0 | 1024.0 | 436 | 6.40 | 337.0 | 2032.0 | 754 | 6.03 | 467.0 | 2212.0 | 704 | 4.74 | ||||||||||||
2092 | Sole/Wasser | Nibe F1155-6 | 3.3 | 2018 | 220 | 4 | 3027.0 | 14249.0 | 4636 | 4.71 | 494.0 | 2392.0 | 712 | 4.84 | 544.0 | 2558.0 | 668 | 4.70 | 522.0 | 2456.0 | 743 | 4.70 | 136.0 | 577.0 | 320 | 4.24 | 65.0 | 171.0 | 55 | 2.63 | 56.0 | 176.0 | 74 | 3.14 | 54.0 | 156.0 | 68 | 2.89 | 49.0 | 117.0 | 49 | 2.39 | 67.0 | 288.0 | 132 | 4.30 | 146.0 | 855.0 | 357 | 5.86 | 377.0 | 2056.0 | 724 | 5.45 | 517.0 | 2447.0 | 734 | 4.73 | ||||||||||||
2092 | Sole/Wasser | Nibe F1155-6 | 3.3 | 2017 | 220 | 4 | 992.0 | 5039.0 | 1625 | 5.08 | 78.0 | 471.0 | 209 | 6.04 | 379.0 | 2077.0 | 701 | 5.48 | 535.0 | 2491.0 | 715 | 4.66 |
NR | 2092 |
Username | Andrej |
Einbaujahr der WP | 2017-10-14 |
PLZ des Wohnortes | 88471 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F1155-6 |
modulierend | Ja |
Leistung (0/35) | 3.3 kW |
berechneter Primärenergiebedarf | 30.8 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 2.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 220 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Habe bisher bloß meinen eigenen Kollektor verlegt |
Bemerkungen | HTD Kollektor Linear/Gerade auf drei Ebenen ca. 70 m lang plus Anbindung. 2 Rohre 2 m tief, 2 Rohre 1,5 m tief und 2 Rohre 1 m tief, nach jedem Drittel wurden die Ebenen getauscht. |