Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2118 | Luft/Wasser | Nibe F750 | 6.0 | 2023 | 175 | 5 | 2748.0 | 652.0 | 643.0 | 412.0 | 285.0 | 209.0 | 130.0 | 114.0 | 141.0 | 162.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
2118 | Luft/Wasser | Nibe F750 | 6.0 | 2022 | 175 | 4,5 | 613.0 | 179.0 | 434.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2118 | Luft/Wasser | Nibe F750 | 6.0 | 2021 | 175 | 3,5 | 1610.0 | 4449.0 | 2.76 | 789.0 | 2245.0 | 2.85 | 821.0 | 2204.0 | 2.68 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
2118 | Luft/Wasser | Nibe F750 | 6.0 | 2020 | 175 | 3 | 3865.0 | 3600.0 | 3.55 | 535.0 | 1827.0 | 3.41 | 479.0 | 1773.0 | 3.70 | 443.0 | 347.0 | 208.0 | 180.0 | 123.0 | 150.0 | 130.0 | 300.0 | 390.0 | 580.0 | |||||||||||||||||||||||||||||||||||||||||||||
2118 | Luft/Wasser | Nibe F750 | 6.0 | 2019 | 175 | 2,5 | 3732.0 | 4639.0 | 2.94 | 708.0 | 458.0 | 395.0 | 250.0 | 213.0 | 90.0 | 12.0 | 27.0 | 80.0 | 190.0 | 2.38 | 290.0 | 1130.0 | 3.90 | 689.0 | 1527.0 | 2.22 | 520.0 | 1792.0 | 3.45 | |||||||||||||||||||||||||||||||||||||||||
2118 | Luft/Wasser | Nibe F750 | 6.0 | 2018 | 175 | 2 | 4060.0 | 642.0 | 736.0 | 613.0 | 244.0 | 146.0 | 94.0 | 91.0 | 118.0 | 141.0 | 222.0 | 476.0 | 537.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
2118 | Luft/Wasser | Nibe F750 | 6.0 | 2017 | 175 | 2 | 4753.0 | 1168.0 | 969.0 | 473.0 | 293.0 | 157.0 | 112.0 | 121.0 | 118.0 | 143.0 | 166.0 | 481.0 | 552.0 |
NR | 2118 |
Username | wisley |
Einbaujahr der WP | 2016-11-01 |
PLZ des Wohnortes | 27639 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F750 |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 56.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Abluft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 65 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 45.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 175 m² |
Lüftung | dezKWLWR |
Personen | 2,5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Wichtig!!! Seit Juli ist eine PV Anlage installiert. Bei Fragen zur Nutzungsoptimierung mit PV kann ich gerne weiterhelfen. |