Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 212 | Luft/Wasser | Ochsner OLWI 9 | 7.1 | 2011 | 215 | 4 | 3132.0 | 6147.0 | 1200 | 1.96 | 1367.0 | 2574.0 | 504 | 1.88 | 1152.0 | 2208.0 | 443 | 1.92 | 539.0 | 1170.0 | 223 | 2.17 | 74.0 | 195.0 | 30 | 2.64 | ||||||||||||||||||||||||||||||||||||||||||||
| 212 | Luft/Wasser | Ochsner OLWI 9 | 7.1 | 2010 | 215 | 4 | 6801.0 | 14480.0 | 2127 | 2.13 | 2484.0 | 3988.0 | 518 | 1.61 | 1473.0 | 3235.0 | 495 | 2.20 | 930.0 | 2256.0 | 337 | 2.43 | 329.0 | 953.0 | 137 | 2.90 | 240.0 | 748.0 | 102 | 3.12 | 10.0 | 34.0 | 5 | 3.40 | 0 | 0 | 0 | 20.0 | 58.0 | 2 | 2.90 | 100.0 | 301.0 | 44 | 3.01 | 434.0 | 1116.0 | 172 | 2.57 | 781.0 | 1791.0 | 315 | 2.29 | |||||||||||||||||
| 212 | Luft/Wasser | Ochsner OLWI 9 | 7.1 | 2009 | 215 | 4 | 2582.0 | 5867.0 | 991 | 2.27 | 514.0 | 1202.0 | 189 | 2.34 | 770.0 | 1907.0 | 280 | 2.48 | 1298.0 | 2758.0 | 522 | 2.12 |
| NR | 212 |
| Username | cbv.net |
| Einbaujahr der WP | 2009-09-17 |
| PLZ des Wohnortes | 61197 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Ochsner OLWI 9 |
| modulierend | |
| Leistung (0/35) | 7.1 kW |
| berechneter Endenergiebedarf | 60.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 40 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | > erfasst: |
| WMZ | |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 40.0 °C |
| Heizung max. Vorlauf Temp. | 35.0 °C |
| Spreizung Heizkr. | 5.0 |
| Heizflaeche | 215 m² |
| Lüftung | zenKWLWR |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |