Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2120 | Sole/Wasser | NIBE F1155-6 | 3.2 | 2023 | 168 | 5 | 1780.0 | 9606.0 | 3099 | 5.40 | 442.5 | 2534.0 | 745 | 5.73 | 394.3 | 2136.0 | 654 | 5.42 | 377.2 | 2031.0 | 715 | 5.38 | 294.6 | 1650.0 | 620 | 5.60 | 116.6 | 615.0 | 213 | 5.27 | 45.3 | 180.0 | 42 | 3.97 | 36.6 | 140.0 | 33 | 3.83 | 29.9 | 126.0 | 30 | 4.21 | 43.0 | 194.0 | 47 | 4.51 | ||||||||||||||||||||||||
2120 | Sole/Wasser | NIBE F1155-6 | 3.2 | 2022 | 168 | 5 | 2719.5 | 15332.0 | 4794 | 5.64 | 480.0 | 2626.0 | 744 | 5.47 | 401.0 | 2195.0 | 671 | 5.47 | 390.0 | 2098.0 | 681 | 5.38 | 285.0 | 1597.0 | 559 | 5.60 | 60.0 | 238.0 | 62 | 3.97 | 32.0 | 116.0 | 28 | 3.63 | 44.0 | 173.0 | 44 | 3.93 | 43.0 | 177.0 | 44 | 4.12 | 105.0 | 687.0 | 239 | 6.54 | 131.1 | 889.0 | 337 | 6.78 | 287.9 | 1853.0 | 661 | 6.44 | 460.5 | 2683.0 | 724 | 5.83 | ||||||||||||
2120 | Sole/Wasser | NIBE F1155-6 | 3.2 | 2021 | 168 | 5 | 3065.6 | 17196.0 | 5596 | 5.61 | 555.4 | 3004.0 | 739 | 5.41 | 467.4 | 2419.0 | 644 | 5.18 | 411.6 | 2214.0 | 711 | 5.38 | 327.6 | 1802.0 | 645 | 5.50 | 173.9 | 989.0 | 430 | 5.69 | 37.6 | 154.0 | 52 | 4.10 | 36.5 | 156.0 | 63 | 4.27 | 42.5 | 234.0 | 105 | 5.51 | 58.1 | 355.0 | 164 | 6.11 | 175.0 | 1235.0 | 587 | 7.06 | 311.0 | 1985.0 | 718 | 6.38 | 469.0 | 2649.0 | 738 | 5.65 | ||||||||||||
2120 | Sole/Wasser | NIBE F1155-6 | 3.2 | 2020 | 168 | 5 | 2521.5 | 15278.0 | 5284 | 6.06 | 434.4 | 2528.0 | 738 | 5.82 | 373.0 | 2183.0 | 705 | 5.85 | 367.2 | 2116.0 | 699 | 5.76 | 196.1 | 1140.0 | 477 | 5.81 | 152.0 | 792.0 | 324 | 5.21 | 37.9 | 166.0 | 59 | 4.38 | 32.7 | 142.0 | 60 | 4.34 | 25.6 | 111.0 | 46 | 4.34 | 58.1 | 383.0 | 160 | 6.59 | 167.7 | 1294.0 | 574 | 7.72 | 267.8 | 1901.0 | 694 | 7.10 | 409.0 | 2522.0 | 748 | 6.17 | ||||||||||||
2120 | Sole/Wasser | NIBE F1155-6 | 3.2 | 2019 | 168 | 4 | 2665.2 | 15556.0 | 5005 | 5.84 | 585.0 | 3669.0 | 734 | 6.27 | 416.0 | 2185.0 | 661 | 5.25 | 334.1 | 1898.0 | 706 | 5.68 | 194.1 | 1076.0 | 417 | 5.54 | 163.9 | 933.0 | 382 | 5.69 | 42.0 | 98.0 | 29 | 2.33 | 48.6 | 137.0 | 37 | 2.82 | 44.5 | 114.0 | 30 | 2.56 | 52.0 | 228.0 | 92 | 4.38 | 144.0 | 1006.0 | 459 | 6.99 | 265.0 | 1823.0 | 710 | 6.88 | 376.0 | 2389.0 | 748 | 6.35 | ||||||||||||
2120 | Sole/Wasser | NIBE F1155-6 | 3.2 | 2018 | 168 | 4 | 3134.1 | 19666.0 | 3816 | 6.27 | 562.3 | 3741.0 | 628 | 6.65 | 808.7 | 4618.0 | 702 | 5.71 | 489.4 | 3036.0 | 727 | 6.20 | 138.8 | 783.0 | 312 | 5.64 | 76.1 | 343.0 | 118 | 4.51 | 52.0 | 160.5 | 34 | 3.09 | 52.0 | 160.5 | 27 | 3.09 | 46.8 | 157.0 | 36 | 3.35 | 69.1 | 413.0 | 110 | 5.98 | 126.5 | 1054.0 | 363 | 8.33 | 283.4 | 2223.0 | 7.84 | 429.0 | 2977.0 | 759 | 6.94 | |||||||||||||
2120 | Sole/Wasser | NIBE F1155-6 | 3.2 | 2017 | 168 | 404.0 | 2827.0 | 454 | 7.00 | 404.0 | 2827.0 | 454 | 7.00 |
NR | 2120 |
Username | Hopfensack |
Einbaujahr der WP | 2017-12-12 |
PLZ des Wohnortes | 01877 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | NIBE F1155-6 |
modulierend | Ja |
Leistung (0/35) | 3.2 kW |
berechneter Primärenergiebedarf | 30.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 2.8 m |
Fläche | 130 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 2.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 168 m² |
Lüftung | Fenster |
Personen | 5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Ja |
Bemerkungen | Wärmepumpe inklusive Zirkulationspumpe über eigenen Stromzähler. 3 Kreise a 300m |