Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
213 | Luft/Wasser | tecalor THZ403 sol | 6.0 | 2015 | 160 | 2 | 1206.0 | 4004.0* | 3.32 | 364.0 | 810.0 | 2.61 | 335.0 | 804.0 | 2.82 | 225.0 | 565.0 | 3.13 | 115.0 | 339.0 | 4.17 | 93.0 | 316.0 | 4.90 | 55.0 | 155.0 | 5.36 | 19.0 | 35.0 | 9.21 | ||||||||||||||||||||||||||||||||||||||||
213 | Luft/Wasser | tecalor THZ403 sol | 6.0 | 2014 | 160 | 2033.0 | 5529.0* | 2.72 | 461.0 | 1186.0 | 2.57 | 278.0 | 684.0 | 2.46 | 127.0 | 352.0 | 2.77 | 154.0 | 513.0 | 3.33 | 86.0 | 322.0 | 3.74 | 34.0 | 178.0 | 5.24 | 22.0 | 91.0 | 4.14 | 45.0 | 128.0 | 2.84 | 45.0 | 128.0 | 2.84 | 106.0 | 272.0 | 2.57 | 290.0 | 746.0 | 2.57 | 385.0 | 929.0 | 2.41 | ||||||||||||||||||||||||||
213 | Luft/Wasser | tecalor THZ403 sol | 6.0 | 2013 | 160 | 2 | 2434.0 | 8131.0* | 3.34 | 521.0 | 1216.0 | 2.60 | 400.0 | 998.0 | 2.85 | 278.0 | 782.0 | 3.32 | 147.0 | 504.0 | 4.38 | 90.0 | 266.0 | 4.51 | 59.0 | 162.0 | 5.12 | 19.0 | 93.0 | 12.26 | 20.0 | 112.0 | 12.60 | 87.0 | 292.0 | 4.97 | 182.0 | 451.0 | 3.25 | 266.0 | 672.0 | 3.05 | 365.0 | 903.0 | 2.86 | |||||||||||||||||||||||||
213 | Luft/Wasser | tecalor THZ403 sol | 6.0 | 2012 | 160 | 2 | 2255.0 | 7570.0* | 3.36 | 360.0 | 1089.0 | 3.41 | 428.0 | 1072.0 | 2.83 | 202.0 | 482.0 | 3.08 | 183.0 | 464.0 | 3.30 | 75.0 | 241.0 | 5.08 | 76.0 | 208.0 | 4.58 | 29.0 | 130.0 | 9.31 | 19.0 | 94.0 | 12.32 | 74.0 | 269.0 | 5.53 | 158.0 | 359.0 | 3.16 | 271.0 | 636.0 | 2.86 | 380.0 | 846.0 | 2.59 | |||||||||||||||||||||||||
213 | Luft/Wasser | tecalor THZ403 sol | 6.0 | 2011 | 160 | 2 | 1890.0 | 5941.0* | 3.14 | 355.0 | 836.0 | 2.75 | 347.0 | 814.0 | 2.75 | 189.0 | 502.0 | 3.40 | 68.0 | 173.0 | 4.60 | 50.0 | 123.0 | 5.26 | 30.0 | 56.0 | 6.53 | 36.0 | 48.0 | 5.22 | 35.0 | 57.0 | 5.63 | 49.0 | 105.0 | 5.00 | 131.0 | 233.0 | 2.85 | 260.0 | 577.0 | 2.76 | 340.0 | 737.0 | 2.58 | |||||||||||||||||||||||||
213 | Luft/Wasser | tecalor THZ403 sol | 6.0 | 2010 | 160 | 2 | 2464.3 | 7584.0* | 3.08 | 485.0 | 1325.0 | 3.02 | 401.0 | 1050.0 | 2.97 | 207.0 | 562.0 | 3.39 | 113.0 | 254.0 | 3.49 | 121.0 | 240.0 | 3.14 | 50.0 | 69.0 | 4.18 | 23.0 | 31.0 | 7.43 | 46.0 | 74.0 | 4.65 | 63.3 | 102.0 | 3.82 | 134.0 | 277.0 | 3.11 | 292.0 | 662.0 | 2.75 | 529.0 | 1258.0 | 2.64 | |||||||||||||||||||||||||
213 | Luft/Wasser | tecalor THZ403 sol | 6.0 | 2009 | 160 | 2 | 2403.0 | 8084.0* | 3.36 | 552.0 | 1593.0 | 3.14 | 416.0 | 1224.0 | 3.28 | 292.0 | 773.0 | 3.13 | 87.0 | 218.0 | 4.11 | 62.0 | 134.0 | 4.42 | 43.0 | 94.0 | 5.44 | 20.0 | 40.0 | 9.00 | 16.0 | 34.0 | 10.88 | 26.0 | 54.0 | 7.46 | 170.0 | 358.0 | 2.93 | 227.0 | 531.0 | 2.96 | 492.0 | 1351.0 | 3.03 |
NR | 213 |
Username | Hati 50 |
Einbaujahr der WP | 2008-11-01 |
PLZ des Wohnortes | 21224 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | tecalor THZ403 sol |
modulierend | |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 39.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2000 Watt DB |
elektr. Verbrauch HP gem./DB | 60 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 28.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 160 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Luft Erdwärmetauscher, 2x 25m, Rohr NW 200, Der angebene Stromverbrauch beinhaltet den gesamten Strom für Wärmepumpe, Heizung- und/Solarumwälzung, Solarsteuerung, Wohnraumlüftung. |