Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2198 | Luft/Wasser | Samsung AE090/Bösch SLS9D | 9.0 | 2023 | 109 | 2 | 3729.0 | 13928.0 | 3.80 | 759.0 | 2789.0 | 3.67 | 638.0 | 2315.0 | 3.63 | 476.0 | 2046.0 | 4.30 | 395.0 | 1797.0 | 4.55 | 121.0 | 586.0 | 4.84 | 43.0 | 31.0 | 0.72 | 62.0 | 0 | 57.0 | 15.0 | 0.26 | 17.0 | 6.0 | 0.35 | 103.0 | 466.0 | 4.52 | 462.0 | 1792.0 | 3.88 | 596.0 | 2085.0 | 3.50 | ||||||||||||||||||||||||||
2198 | Luft/Wasser | Samsung AE090/Bösch SLS9D | 9.0 | 2022 | 109 | 2 | 4255.6 | 15660.0 | 3.76 | 810.3 | 2937.0 | 3.62 | 757.8 | 2819.0 | 3.72 | 587.2 | 2319.0 | 3.95 | 343.1 | 1534.0 | 4.47 | 95.0 | 394.0 | 4.15 | 61.6 | 7.0 | 0.11 | 93.2 | 66.1 | 8.0 | 0.12 | 89.9 | 426.0 | 4.74 | 91.9 | 466.0 | 5.07 | 450.8 | 1897.0 | 4.21 | 808.7 | 2853.0 | 3.53 | |||||||||||||||||||||||||||
2198 | Luft/Wasser | Samsung AE090/Bösch SLS9D | 9.0 | 2021 | 109 | 2 | 5372.4 | 19280.0 | 3.59 | 961.2 | 3092.0 | 3.22 | 672.4 | 2455.0 | 3.65 | 640.2 | 2517.0 | 3.93 | 466.3 | 1942.0 | 4.16 | 261.6 | 1273.0 | 4.87 | 119.2 | 1.0 | 0.01 | 95.1 | 4.0 | 0.04 | 69.6 | 151.0 | 2.17 | 83.4 | 390.0 | 4.68 | 373.2 | 1627.0 | 4.36 | 655.2 | 2537.0 | 3.87 | 975.0 | 3291.0 | 3.38 | |||||||||||||||||||||||||
2198 | Luft/Wasser | Samsung AE090/Bösch SLS9D | 9.0 | 2020 | 109 | 2 | 911.0 | 3180.0 | 3.49 | 911.0 | 3180.0 | 3.49 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2198 | Luft/Wasser | Samsung AE090/Bösch SLS9D | 9.0 | 2019 | 109 | 2 | 5927.9 | 21583.0 | 3.69 | 1545.3 | 4802.0 | 3.11 | 901.8 | 3237.0 | 3.59 | 616.0 | 2638.0 | 4.28 | 403.0 | 1902.0 | 4.72 | 326.0 | 1482.0 | 4.55 | 123.0 | 1.0 | 0.01 | 73.9 | 0 | 63.2 | 10.0 | 0.16 | 135.2 | 674.0 | 4.99 | 319.6 | 1513.0 | 4.73 | 578.0 | 2428.0 | 4.20 | 842.9 | 2896.0 | 3.44 | ||||||||||||||||||||||||||
2198 | Luft/Wasser | Samsung AE090/Bösch SLS9D | 9.0 | 2018 | 109 | 2 | 3506.5 | 12670.0 | 3.61 | 293.0 | 1329.0 | 4.54 | 170.8 | 677.0 | 3.96 | 92.8 | 320.0 | 3.45 | 98.3 | 211.0 | 2.15 | 172.6 | 249.0 | 1.44 | 154.7 | 646.0 | 4.18 | 386.1 | 1896.0 | 4.91 | 805.8 | 3141.0 | 3.90 | 1332.4 | 4201.0 | 3.15 |
NR | 2198 |
Username | Lokheizer |
Einbaujahr der WP | 2017-12-20 |
PLZ des Wohnortes | A-8772 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Samsung AE090/Bösch SLS9D |
modulierend | Ja |
Leistung (0/35) | 9.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 44 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 3000 Watt gem. |
elektr. Verbrauch HP gem./DB | 70 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 109 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Inbetriebnahme 20.12.2017 Einzug 05.04.2018 --- Durch den starken Kühlbedarf 2019 durch fehlende Verschattung und der Installation einer Solaranlage für Warmwasser kam es zu einem Verbrauch an Strom ohne durch den WMZ gezählte erzeugte Wärme. Deshalb die AZ von 0. ;) |