Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2267 | Luft/Wasser | Höcker - cop-star 200 PI | 19.3 | 2024 | 270 | 2 | 4757.0 | 18010.0 | 1057 | 3.79 | 1644.0 | 6188.0 | 370 | 3.76 | 899.0 | 3581.0 | 205 | 3.98 | 892.0 | 3462.0 | 204 | 3.88 | 655.0 | 2446.0 | 144 | 3.73 | 305.0 | 1131.0 | 65 | 3.71 | 195.0 | 642.0 | 38 | 3.29 | 101.0 | 350.0 | 18 | 3.47 | 66.0 | 210.0 | 13 | 3.18 | ||||||||||||||||||||||||||||
2267 | Luft/Wasser | Höcker - cop-star 200 PI | 19.3 | 2023 | 270 | 2 | 2733.0 | 10336.0 | 614 | 3.78 | 428.0 | 1565.0 | 94 | 3.66 | 970.0 | 3651.0 | 217 | 3.76 | 1335.0 | 5120.0 | 303 | 3.84 | ||||||||||||||||||||||||||||||||||||||||||||||||
2267 | Luft/Wasser | Höcker - cop-star 200 PI | 19.3 | 2022 | 270 | 2 | 4653.0 | 18379.0 | 1163 | 3.95 | 1615.0 | 5843.0 | 376 | 3.62 | 1189.0 | 4315.0 | 272 | 3.63 | 1748.0 | 7295.0 | 459 | 4.17 | 101.0 | 926.0 | 56 | 9.17 | ||||||||||||||||||||||||||||||||||||||||||||
2267 | Luft/Wasser | Höcker - cop-star 200 PI | 19.3 | 2021 | 270 | 2 | 9877.0 | 34464.0 | 2273 | 3.49 | 1792.0 | 6170.0 | 412 | 3.44 | 1501.0 | 5039.0 | 332 | 3.36 | 1266.0 | 4432.0 | 290 | 3.50 | 940.0 | 3191.0 | 213 | 3.39 | 529.0 | 1921.0 | 119 | 3.63 | 111.0 | 354.0 | 25 | 3.19 | 92.0 | 298.0 | 21 | 3.24 | 90.0 | 279.0 | 20 | 3.10 | 209.0 | 711.0 | 45 | 3.40 | 677.0 | 2476.0 | 181 | 3.66 | 1204.0 | 4295.0 | 276 | 3.57 | 1466.0 | 5298.0 | 339 | 3.61 | ||||||||||||
2267 | Luft/Wasser | Höcker - cop-star 200 PI | 19.3 | 2020 | 270 | 2 | 8830.0 | 30479.0 | 1947 | 3.45 | 1650.0 | 5906.0 | 371 | 3.58 | 1213.0 | 4082.0 | 264 | 3.37 | 1180.0 | 3921.0 | 258 | 3.32 | 573.0 | 2085.0 | 118 | 3.64 | 370.0 | 1378.0 | 82 | 3.72 | 156.0 | 548.0 | 35 | 3.51 | 82.0 | 240.0 | 20 | 2.93 | 73.0 | 234.0 | 15 | 3.21 | 127.0 | 413.0 | 25 | 3.25 | 552.0 | 1950.0 | 102 | 3.53 | 1201.0 | 4088.0 | 274 | 3.40 | 1653.0 | 5634.0 | 383 | 3.41 | ||||||||||||
2267 | Luft/Wasser | Höcker - cop-star 200 PI | 19.3 | 2019 | 270 | 2 | 8867.0 | 30815.0 | 1963 | 3.48 | 1785.0 | 6224.0 | 390 | 3.49 | 1347.0 | 4772.0 | 302 | 3.54 | 1097.0 | 3616.0 | 240 | 3.30 | 604.0 | 2006.0 | 132 | 3.32 | 500.0 | 1908.0 | 114 | 3.82 | 80.0 | 257.0 | 20 | 3.21 | 83.0 | 263.0 | 18 | 3.17 | 78.0 | 242.0 | 17 | 3.10 | 167.0 | 584.0 | 34 | 3.50 | 479.0 | 1751.0 | 105 | 3.66 | 1170.0 | 4016.0 | 261 | 3.43 | 1477.0 | 5176.0 | 330 | 3.50 | ||||||||||||
2267 | Luft/Wasser | Höcker - cop-star 200 PI | 19.3 | 2018 | 270 | 2 | 3222.0 | 11138.0 | 308 | 3.46 | 659.0 | 2391.0 | 3.63 | 1155.0 | 3946.0 | 3.42 | 1408.0 | 4801.0 | 308 | 3.41 |
NR | 2267 |
Username | Urstoff |
Einbaujahr der WP | 2016-11-28 |
PLZ des Wohnortes | 91126 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Höcker - cop-star 200 PI |
modulierend | Ja |
Leistung (0/35) | 19.3 kW |
berechneter Primärenergiebedarf | 87.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 270 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Baudenkmal Bj. 1740 ab April 2022 mit PV-Unterstützung |