Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2291 | Wasser/Wasser | iDM -TERRA SW 10 | 10.6 | 2026 | 180 | 5 | 846.2 | 3497.7 | 275 | 4.13 | 846.2 | 3497.7 | 275 | 4.13 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2291 | Wasser/Wasser | iDM -TERRA SW 10 | 10.6 | 2025 | 180 | 5 | 4520.8 | 18639.0 | 1509 | 4.12 | 724.0 | 3073.0 | 247 | 4.24 | 788.4 | 3289.7 | 266 | 4.17 | 473.3 | 1956.1 | 160 | 4.13 | 426.7 | 1747.5 | 143 | 4.10 | 281.2 | 1123.0 | 90 | 3.99 | 86.5 | 261.7 | 22 | 3.03 | 78.2 | 239.5 | 20 | 3.06 | 81.9 | 252.5 | 21 | 3.08 | 89.3 | 284.2 | 23 | 3.18 | 406.3 | 1695.8 | 137 | 4.17 | 491.6 | 2108.7 | 170 | 4.29 | 593.4 | 2607.3 | 210 | 4.39 | ||||||||||||
| 2291 | Wasser/Wasser | iDM -TERRA SW 10 | 10.6 | 2024 | 180 | 5 | 5017.6 | 19097.8 | 1559 | 3.81 | 1020.0 | 3909.0 | 321 | 3.83 | 811.0 | 3310.0 | 271 | 4.08 | 613.0 | 2489.0 | 203 | 4.06 | 397.0 | 1465.2 | 120 | 3.69 | 224.6 | 732.8 | 61 | 3.26 | 115.3 | 269.2 | 24 | 2.33 | 123.2 | 292.6 | 26 | 2.38 | 91.9 | 215.2 | 19 | 2.34 | 162.6 | 448.5 | 38 | 2.76 | 262.0 | 948.2 | 77 | 3.62 | 611.0 | 2538.6 | 203 | 4.15 | 586.0 | 2479.5 | 196 | 4.23 | ||||||||||||
| 2291 | Wasser/Wasser | iDM -TERRA SW 10 | 10.6 | 2023 | 180 | 5 | 2292.0 | 8466.0 | 679 | 3.69 | 369.0 | 1365.0 | 110 | 3.70 | 888.0 | 3310.0 | 264 | 3.73 | 1035.0 | 3791.0 | 305 | 3.66 | ||||||||||||||||||||||||||||||||||||||||||||||||
| 2291 | Wasser/Wasser | iDM -TERRA SW 10 | 10.6 | 2021 | 180 | 4 | 2557.8 | 8377.4 | 686 | 3.28 | 570.0 | 1847.0 | 150 | 3.24 | 522.0 | 1648.0 | 137 | 3.16 | 507.0 | 1731.4 | 140 | 3.41 | 380.8 | 1261.0 | 103 | 3.31 | 578.0 | 1890.0 | 156 | 3.27 | ||||||||||||||||||||||||||||||||||||||||
| 2291 | Wasser/Wasser | iDM -TERRA SW 10 | 10.6 | 2020 | 180 | 4 | 3272.1 | 10456.9 | 856 | 3.20 | 575.3 | 1848.8 | 151 | 3.21 | 522.8 | 1719.1 | 140 | 3.29 | 406.0 | 1300.5 | 108 | 3.20 | 345.0 | 1086.5 | 90 | 3.15 | 97.0 | 233.0 | 21 | 2.40 | 81.0 | 180.0 | 14 | 2.22 | 79.0 | 196.0 | 16 | 2.48 | 277.0 | 908.0 | 75 | 3.28 | 431.0 | 1451.0 | 117 | 3.37 | 458.0 | 1534.0 | 124 | 3.35 | ||||||||||||||||||||
| 2291 | Wasser/Wasser | iDM -TERRA SW 10 | 10.6 | 2019 | 180 | 4 | 1987.2 | 6593.1 | 522 | 3.32 | 740.0 | 2266.0 | 178 | 3.06 | 386.1 | 1426.0 | 111 | 3.69 | 256.1 | 948.1 | 75 | 3.70 | 211.0 | 692.0 | 57 | 3.28 | 394.0 | 1261.0 | 101 | 3.20 | ||||||||||||||||||||||||||||||||||||||||
| 2291 | Wasser/Wasser | iDM -TERRA SW 10 | 10.6 | 2018 | 180 | 2 | 2069.9 | 6625.8 | 514 | 3.20 | 614.9 | 1782.8 | 148 | 2.90 | 412.7 | 1450.4 | 110 | 3.51 | 206.0 | 693.0 | 53 | 3.36 | 307.0 | 990.0 | 75 | 3.22 | 529.3 | 1709.6 | 128 | 3.23 |
| NR | 2291 |
| Username | Thomas |
| Einbaujahr der WP | 2017-12-28 |
| PLZ des Wohnortes | MKD |
| Bauart | Wasser/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | iDM -TERRA SW 10 |
| modulierend | Nein |
| Leistung (0/35) | 10.6 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 49 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Förder- und Schluckbrunnen |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 2210 Watt DB |
| elektr. Verbrauch HP gem./DB | 45 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.5 °C |
| Mittlere Wärmequellentemperatur | 10.0 °C |
| Heizung max. Vorlauf Temp. | 46.0 °C |
| Spreizung Heizkr. | 6.0 |
| Heizflaeche | 180 m² |
| Lüftung | Fenster |
| Personen | 3-5 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | die WP war bis Juni 2020 nur für die kältere Monate im Betrieb. Seit Juli 2020 Ist IDM Hygienik für Warmwasser eingebaut. HINWEIS: Zwischen 12.2021 bis 09.2023 wegen defekten Displäy am Stromzähler, fehlen die daten. - Seit 01.2024 Frequenzumrichter eingebaut auf 33HZ- Brunnenpumpe ist lowara 2gs02 |