Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2297 | Sole/Wasser | Viessmann Vitocal 333-G.B06 | 5.7 | 2023 | 180 | 3 | 1172.1 | 6699.6 | 1033 | 5.72 | 249.2 | 1422.7 | 230 | 5.71 | 161.9 | 889.6 | 148 | 5.49 | 122.6 | 661.8 | 109 | 5.40 | 117.6 | 647.4 | 103 | 5.51 | 70.2 | 375.6 | 56 | 5.35 | 27.1 | 118.4 | 16 | 4.37 | 23.8 | 108.0 | 14 | 4.54 | 30.9 | 145.1 | 19 | 4.70 | 20.8 | 97.4 | 12 | 4.68 | 27.1 | 170.5 | 22 | 6.29 | 142.3 | 996.2 | 139 | 7.00 | 178.6 | 1066.9 | 165 | 5.97 | ||||||||||||
2297 | Sole/Wasser | Viessmann Vitocal 333-G.B06 | 5.7 | 2022 | 180 | 3 | 1093.3 | 6157.1 | 968 | 5.63 | 217.0 | 1189.0 | 201 | 5.48 | 170.4 | 916.3 | 157 | 5.38 | 172.4 | 928.3 | 155 | 5.38 | 93.5 | 508.9 | 82 | 5.44 | 33.9 | 168.4 | 25 | 4.97 | 24.1 | 121.4 | 15 | 5.04 | 20.7 | 98.5 | 12 | 4.76 | 22.9 | 110.0 | 13 | 4.80 | 19.9 | 107.2 | 13 | 5.39 | 24.7 | 142.9 | 18 | 5.79 | 113.7 | 791.7 | 111 | 6.96 | 180.1 | 1074.5 | 166 | 5.97 | ||||||||||||
2297 | Sole/Wasser | Viessmann Vitocal 333-G.B06 | 5.7 | 2021 | 180 | 3 | 1401.5 | 7847.0 | 1292 | 5.60 | 265.3 | 1431.7 | 245 | 5.40 | 191.4 | 1008.1 | 174 | 5.27 | 174.1 | 942.7 | 160 | 5.41 | 158.1 | 866.7 | 143 | 5.48 | 77.2 | 444.3 | 68 | 5.76 | 31.6 | 156.3 | 57 | 4.95 | 20.6 | 103.3 | 13 | 5.01 | 18.1 | 91.1 | 11 | 5.03 | 27.8 | 141.8 | 17 | 5.10 | 42.6 | 299.4 | 39 | 7.03 | 144.9 | 942.5 | 137 | 6.50 | 249.8 | 1419.1 | 228 | 5.68 | ||||||||||||
2297 | Sole/Wasser | Viessmann Vitocal 333-G.B06 | 5.7 | 2020 | 180 | 3 | 1165.9 | 6741.1 | 1050 | 5.78 | 255.5 | 1438.2 | 241 | 5.63 | 162.9 | 905.3 | 151 | 5.56 | 134.9 | 741.9 | 123 | 5.50 | 95.3 | 510.6 | 81 | 5.36 | 45.4 | 260.4 | 39 | 5.74 | 29.8 | 149.7 | 21 | 5.02 | 25.3 | 125.1 | 15 | 4.94 | 17.4 | 89.9 | 11 | 5.17 | 26.1 | 124.2 | 15 | 4.76 | 65.5 | 470.7 | 61 | 7.19 | 107.7 | 729.8 | 104 | 6.78 | 200.1 | 1195.3 | 188 | 5.97 | ||||||||||||
2297 | Sole/Wasser | Viessmann Vitocal 333-G.B06 | 5.7 | 2019 | 180 | 3 | 1638.4 | 8894.2 | 1484 | 5.43 | 481.7 | 2439.4 | 442 | 5.06 | 255.5 | 1326.6 | 245 | 5.19 | 199.0 | 1049.9 | 184 | 5.28 | 113.0 | 622.0 | 102 | 5.50 | 82.7 | 473.1 | 71 | 5.72 | 27.0 | 122.0 | 17 | 4.52 | 21.1 | 100.1 | 13 | 4.74 | 26.9 | 129.5 | 15 | 4.81 | 20.7 | 98.5 | 12 | 4.76 | 53.1 | 335.0 | 44 | 6.31 | 156.6 | 1016.2 | 150 | 6.49 | 201.1 | 1181.9 | 189 | 5.88 | ||||||||||||
2297 | Sole/Wasser | Viessmann Vitocal 333-G.B06 | 5.7 | 2018 | 180 | 3 | 444.0 | 1842.5 | 316 | 4.15 | 444.0 | 1842.5 | 316 | 4.15 |
NR | 2297 |
Username | renem |
Einbaujahr der WP | 2018-11-05 |
PLZ des Wohnortes | 86316 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Viessmann Vitocal 333-G.B06 |
modulierend | Nein |
Leistung (0/35) | 5.7 kW |
berechneter Primärenergiebedarf | 24.7 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.8 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 4.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 180 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Keine |
Bemerkungen | HTD RGK 2x300m Slinky-Verlegung im Garten. Davon ca. 2x80m als Baugruben-Kollektor auf der Nordseite |