Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2325 | Sole/Wasser | Hautec | 12.4 | 2018 | 180 | 3 | 6146.0 | 12902.0 | 1907 | 2.10 | 473.0 | 1114.0 | 164 | 2.36 | 427.0 | 1007.0 | 149 | 2.36 | 473.0 | 1114.0 | 164 | 2.36 | 458.0 | 1078.0 | 159 | 2.35 | 473.0 | 1114.0 | 164 | 2.36 | 458.0 | 1078.0 | 159 | 2.35 | 473.0 | 1078.0 | 164 | 2.28 | 473.0 | 1114.0 | 164 | 2.36 | 458.0 | 1078.0 | 159 | 2.35 | 473.0 | 1114.0 | 164 | 2.36 | 617.0 | 1078.0 | 159 | 1.75 | 890.0 | 935.0 | 138 | 1.05 | ||||||||||||
2325 | Sole/Wasser | Hautec | 12.4 | 2017 | 180 | 3 | 4569.0 | 12798.0 | 1422 | 2.80 | 1000.0 | 2332.0 | 339 | 2.33 | 788.0 | 1965.0 | 264 | 2.49 | 394.0 | 1121.0 | 123 | 2.85 | 260.0 | 805.0 | 76 | 3.10 | 269.0 | 832.0 | 78 | 3.09 | 261.0 | 805.0 | 76 | 3.08 | 269.0 | 832.0 | 78 | 3.09 | 269.0 | 832.0 | 79 | 3.09 | 261.0 | 805.0 | 76 | 3.08 | 278.0 | 859.0 | 81 | 3.09 | 260.0 | 805.0 | 76 | 3.10 | 260.0 | 805.0 | 76 | 3.10 | ||||||||||||
2325 | Sole/Wasser | Hautec | 12.4 | 2016 | 180 | 3 | 5296.0 | 7721.0 | 1550 | 1.46 | 916.0 | 913.0 | 169 | 1.00 | 807.0 | 731.0 | 254 | 0.91 | 862.0 | 781.0 | 271 | 0.91 | 331.0 | 526.0 | 95 | 1.59 | 240.0 | 503.0 | 64 | 2.10 | 232.0 | 487.0 | 62 | 2.10 | 167.0 | 490.0 | 64 | 2.93 | 373.0 | 667.0 | 116 | 1.79 | 361.0 | 645.0 | 112 | 1.79 | 385.0 | 688.0 | 119 | 1.79 | 361.0 | 645.0 | 112 | 1.79 | 261.0 | 645.0 | 112 | 2.47 | ||||||||||||
2325 | Sole/Wasser | Hautec | 12.4 | 2015 | 180 | 3 | 6039.0 | 520.0 | 457.0 | 507.0 | 490.0 | 507.0 | 490.0 | 507.0 | 507.0 | 490.0 | 507.0 | 497.0 | 560.0 |
NR | 2325 |
Username | Erhard |
Einbaujahr der WP | 2010-10-01 |
PLZ des Wohnortes | 33803 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Hautec |
modulierend | |
Leistung (0/35) | 12.4 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 55 °C |
WW Legionellenschaltung | wöchentlich |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 125.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2500 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 20 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 180 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |