Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2371 | Luft/Wasser | Hoval - Ultra Source Compact | 5.9 | 2024 | 180 | 4 | 1241.0 | 4945.0 | 953 | 3.98 | 568.0 | 2123.0 | 467 | 3.74 | 365.0 | 1497.0 | 240 | 4.10 | 308.0 | 1325.0 | 246 | 4.30 | ||||||||||||||||||||||||||||||||||||||||||||||||
2371 | Luft/Wasser | Hoval - Ultra Source Compact | 5.9 | 2023 | 180 | 4 | 2909.0 | 11784.0 | 2765 | 4.05 | 561.0 | 2043.0 | 363 | 3.64 | 451.0 | 1704.0 | 306 | 3.78 | 281.0 | 1199.0 | 218 | 4.27 | 225.0 | 971.0 | 194 | 4.32 | 100.0 | 423.0 | 80 | 4.23 | 51.0 | 241.0 | 126 | 4.73 | 61.0 | 289.0 | 110 | 4.74 | 117.0 | 491.0 | 157 | 4.20 | 179.0 | 847.0 | 369 | 4.73 | 424.0 | 1699.0 | 369 | 4.01 | 459.0 | 1877.0 | 473 | 4.09 | ||||||||||||||||
2371 | Luft/Wasser | Hoval - Ultra Source Compact | 5.9 | 2022 | 180 | 4 | 2909.0 | 11372.0 | 2307 | 3.91 | 624.0 | 2199.0 | 415 | 3.52 | 402.0 | 1569.0 | 291 | 3.90 | 307.0 | 1312.0 | 215 | 4.27 | 227.0 | 908.0 | 222 | 4.00 | 90.0 | 400.0 | 87 | 4.44 | 60.0 | 293.0 | 118 | 4.88 | 60.0 | 293.0 | 118 | 4.88 | 33.0 | 188.0 | 80 | 5.70 | 112.0 | 491.0 | 166 | 4.38 | 87.0 | 352.0 | 54 | 4.05 | 325.0 | 1370.0 | 204 | 4.22 | 582.0 | 1997.0 | 337 | 3.43 | ||||||||||||
2371 | Luft/Wasser | Hoval - Ultra Source Compact | 5.9 | 2021 | 180 | 4 | 2210.0 | 8932.0 | 2466 | 4.04 | 521.0 | 1987.0 | 600 | 3.81 | 354.0 | 1426.0 | 389 | 4.03 | 353.0 | 1477.0 | 412 | 4.18 | 230.0 | 1011.0 | 233 | 4.40 | 171.0 | 784.0 | 177 | 4.58 | 60.0 | 270.0 | 135 | 4.50 | 521.0 | 1977.0 | 520 | 3.79 | ||||||||||||||||||||||||||||||||
2371 | Luft/Wasser | Hoval - Ultra Source Compact | 5.9 | 2020 | 180 | 4 | 2786.0 | 11519.0 | 3487 | 4.13 | 499.0 | 1937.0 | 429 | 3.88 | 335.0 | 1377.0 | 802 | 4.11 | 335.0 | 1409.0 | 373 | 4.21 | 139.0 | 568.0 | 121 | 4.09 | 139.0 | 618.0 | 127 | 4.45 | 89.0 | 368.0 | 73 | 4.13 | 49.0 | 216.0 | 147 | 4.41 | 56.0 | 250.0 | 104 | 4.46 | 108.0 | 433.0 | 101 | 4.01 | 229.0 | 1077.0 | 276 | 4.70 | 346.0 | 1451.0 | 398 | 4.19 | 462.0 | 1815.0 | 536 | 3.93 | ||||||||||||
2371 | Luft/Wasser | Hoval - Ultra Source Compact | 5.9 | 2019 | 180 | 4 | 2517.0 | 11127.0 | 2682 | 4.42 | 444.0 | 2007.0 | 4.52 | 341.0 | 1536.0 | 568 | 4.50 | 153.0 | 723.0 | 352 | 4.73 | 212.0 | 1012.0 | 286 | 4.77 | 77.0 | 394.0 | 98 | 5.12 | 76.0 | 343.0 | 101 | 4.51 | 71.0 | 318.0 | 98 | 4.48 | 83.0 | 359.0 | 99 | 4.33 | 162.0 | 754.0 | 186 | 4.65 | 428.0 | 1804.0 | 502 | 4.21 | 470.0 | 1877.0 | 392 | 3.99 |
NR | 2371 |
Username | Ultra Source |
Einbaujahr der WP | 2019-02-18 |
PLZ des Wohnortes | 78591 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Hoval - Ultra Source Compact |
modulierend | Ja |
Leistung (0/35) | 5.9 kW |
berechneter Primärenergiebedarf | 1.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 7.9 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 180 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | KFW 40 Haus mit 25 kWP PV-Anlage und Lüftung mit WRG Warmwasser über Frischwasserstation mit 800 ltr Puffer- Speicher /FBH als Direktheizkreis Wärmemenge über eigenen geeichten WMZ erfasst / Ht 0,22 W(m2k) Warmwasserverbrauch über Friwa ca. 3.600 kWh/a Ab 2022 mehr Eigenverbrauch PV, daher ca. 5 Grad höhere VL Temp im Heizkreis normal 27°C ganzjährig ausreichend, ab jetzt 32°C von 08 Uhr - 18 Uhr danach wird abgeschaltet. Daher schlechtere Arbeitszahlen. |