Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2390 | Sole/Wasser | Nibe F1255 | 6.0 | 2025 | 130 | 4 | 1561.0 | 7708.0 | 3454 | 4.94 | 288.0 | 1654.0 | 723 | 5.74 | 261.0 | 1495.0 | 656 | 5.73 | 206.0 | 1086.0 | 533 | 5.27 | 130.0 | 657.0 | 273 | 5.05 | 97.0 | 423.0 | 193 | 4.36 | 57.0 | 157.0 | 57 | 2.75 | 46.0 | 82.0 | 24 | 1.78 | 58.0 | 144.0 | 48 | 2.48 | 84.0 | 318.0 | 144 | 3.79 | 132.0 | 612.0 | 304 | 4.64 | 202.0 | 1080.0 | 499 | 5.35 | ||||||||||||||||
| 2390 | Sole/Wasser | Nibe F1255 | 6.0 | 2024 | 130 | 4 | 1795.0 | 8824.0 | 4112 | 4.92 | 299.0 | 1688.0 | 751 | 5.65 | 219.0 | 1123.0 | 565 | 5.13 | 218.0 | 952.0 | 511 | 4.37 | 132.0 | 570.0 | 230 | 4.32 | 70.0 | 192.0 | 70 | 2.74 | 64.0 | 197.0 | 77 | 3.08 | 60.0 | 148.0 | 49 | 2.47 | 55.0 | 129.0 | 34 | 2.35 | 84.0 | 341.0 | 143 | 4.06 | 128.0 | 705.0 | 300 | 5.51 | 199.0 | 1257.0 | 620 | 6.32 | 267.0 | 1522.0 | 762 | 5.70 | ||||||||||||
| 2390 | Sole/Wasser | Nibe F1255 | 6.0 | 2023 | 130 | 4 | 1687.0 | 7656.0 | 3975 | 4.54 | 250.0 | 1142.0 | 687 | 4.57 | 252.0 | 1128.0 | 680 | 4.48 | 206.0 | 946.0 | 495 | 4.59 | 138.0 | 738.0 | 284 | 5.35 | 78.0 | 349.0 | 146 | 4.47 | 48.0 | 114.0 | 36 | 2.38 | 48.0 | 68.0 | 22 | 1.42 | 52.0 | 111.0 | 34 | 2.13 | 53.0 | 129.0 | 43 | 2.43 | 100.0 | 414.0 | 223 | 4.14 | 214.0 | 1259.0 | 636 | 5.88 | 248.0 | 1258.0 | 689 | 5.07 | ||||||||||||
| 2390 | Sole/Wasser | Nibe F1255 | 6.0 | 2022 | 130 | 4 | 1783.0 | 8024.0 | 4228 | 4.50 | 275.0 | 1405.0 | 728 | 5.11 | 240.0 | 1213.0 | 677 | 5.05 | 224.0 | 1124.0 | 570 | 5.02 | 164.0 | 805.0 | 436 | 4.91 | 81.0 | 308.0 | 141 | 3.80 | 53.0 | 128.0 | 46 | 2.42 | 91.0 | 150.0 | 42 | 1.65 | 80.0 | 288.0 | 157 | 3.60 | 107.0 | 451.0 | 245 | 4.21 | 178.0 | 834.0 | 524 | 4.69 | 290.0 | 1318.0 | 662 | 4.54 | ||||||||||||||||
| 2390 | Sole/Wasser | Nibe F1255 | 6.0 | 2021 | 130 | 4 | 1896.0 | 9638.0 | 4514 | 5.08 | 288.0 | 1729.0 | 766 | 6.00 | 252.0 | 1443.0 | 602 | 5.73 | 221.0 | 1261.0 | 633 | 5.71 | 186.0 | 1003.0 | 417 | 5.39 | 115.0 | 553.0 | 231 | 4.81 | 50.0 | 102.0 | 31 | 2.04 | 56.0 | 106.0 | 32 | 1.89 | 44.0 | 93.0 | 31 | 2.11 | 67.0 | 222.0 | 94 | 3.31 | 111.0 | 498.0 | 266 | 4.49 | 228.0 | 1187.0 | 668 | 5.21 | 278.0 | 1441.0 | 743 | 5.18 | ||||||||||||
| 2390 | Sole/Wasser | Nibe F1255 | 6.0 | 2020 | 130 | 4 | 1609.0 | 7207.0 | 3895 | 4.48 | 260.0 | 1342.0 | 746 | 5.16 | 227.0 | 1141.0 | 674 | 5.03 | 218.0 | 1159.0 | 554 | 5.32 | 100.0 | 424.0 | 182 | 4.24 | 76.0 | 155.0 | 121 | 2.04 | 57.0 | 124.0 | 36 | 2.18 | 52.0 | 111.0 | 33 | 2.13 | 50.0 | 88.0 | 25 | 1.76 | 56.0 | 139.0 | 46 | 2.48 | 111.0 | 458.0 | 253 | 4.13 | 178.0 | 847.0 | 538 | 4.76 | 224.0 | 1219.0 | 687 | 5.44 | ||||||||||||
| 2390 | Sole/Wasser | Nibe F1255 | 6.0 | 2019 | 130 | 4 | 1216.0 | 5516.0 | 2979 | 4.54 | 227.0 | 1014.0 | 609 | 4.47 | 131.0 | 629.0 | 266 | 4.80 | 105.0 | 458.0 | 233 | 4.36 | 52.0 | 91.0 | 36 | 1.75 | 55.0 | 105.0 | 40 | 1.91 | 49.0 | 105.0 | 38 | 2.14 | 67.0 | 228.0 | 108 | 3.40 | 109.0 | 562.0 | 308 | 5.16 | 195.0 | 1081.0 | 603 | 5.54 | 226.0 | 1243.0 | 738 | 5.50 |
| NR | 2390 |
| Username | Fighter1255 |
| Einbaujahr der WP | 2019-02-25 |
| PLZ des Wohnortes | 30161 Ha |
| Bauart | Sole/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Nibe F1255 |
| modulierend | Ja |
| Leistung (0/35) | 6.0 kW |
| berechneter Primärenergiebedarf | 105.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 48 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | 1 Erdbohrung |
| Tiefe | 98.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 2.0 °C |
| Heizung max. Vorlauf Temp. | 35.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 130 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |