Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2429 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2024 | 190 | 3 | 800.0 | 4514.0 | 2069 | 5.64 | 305.0 | 1808.0 | 731 | 5.93 | 200.0 | 1165.0 | 621 | 5.83 | 171.0 | 997.0 | 509 | 5.83 | 83.0 | 417.0 | 172 | 5.02 | 41.0 | 127.0 | 36 | 3.10 | ||||||||||||||||||||||||||||||||||||||||
2429 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2023 | 190 | 3 | 1641.0 | 9353.0 | 4043 | 5.70 | 279.0 | 1727.0 | 718 | 6.19 | 264.0 | 1526.0 | 645 | 5.78 | 236.0 | 1356.0 | 613 | 5.75 | 157.0 | 924.0 | 418 | 5.89 | 50.0 | 196.0 | 68 | 3.92 | 41.0 | 91.0 | 24 | 2.22 | 43.0 | 95.0 | 27 | 2.21 | 40.0 | 85.0 | 25 | 2.13 | 42.0 | 87.0 | 25 | 2.07 | 68.0 | 445.0 | 196 | 6.54 | 179.0 | 1281.0 | 563 | 7.16 | 242.0 | 1540.0 | 721 | 6.36 | ||||||||||||
2429 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2022 | 190 | 3 | 1724.0 | 8540.0 | 3845 | 4.95 | 299.0 | 1625.0 | 792 | 5.43 | 254.0 | 1334.0 | 659 | 5.25 | 231.0 | 1136.0 | 552 | 4.92 | 160.0 | 766.0 | 394 | 4.79 | 65.0 | 154.0 | 59 | 2.37 | 61.0 | 93.0 | 27 | 1.52 | 58.0 | 90.0 | 28 | 1.55 | 60.0 | 85.0 | 24 | 1.42 | 55.0 | 196.0 | 76 | 3.56 | 54.0 | 210.0 | 82 | 3.89 | 149.0 | 1083.0 | 492 | 7.27 | 278.0 | 1768.0 | 660 | 6.36 | ||||||||||||
2429 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2021 | 190 | 3 | 1948.0 | 10094.0 | 4312 | 5.18 | 320.8 | 1942.0 | 736 | 6.05 | 288.9 | 1521.0 | 576 | 5.26 | 235.7 | 1309.0 | 590 | 5.55 | 182.6 | 1022.0 | 489 | 5.60 | 95.3 | 387.0 | 170 | 4.06 | 63.3 | 120.0 | 35 | 1.90 | 70.0 | 139.0 | 42 | 1.99 | 70.4 | 148.0 | 44 | 2.10 | 55.0 | 129.0 | 43 | 2.35 | 102.0 | 605.0 | 278 | 5.93 | 180.0 | 1157.0 | 573 | 6.43 | 284.0 | 1615.0 | 736 | 5.69 | ||||||||||||
2429 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2020 | 190 | 2 | 1473.4 | 7969.0 | 3986 | 5.41 | 220.1 | 1452.0 | 719 | 6.60 | 208.5 | 1248.0 | 677 | 5.99 | 200.8 | 1173.0 | 632 | 5.84 | 80.3 | 302.0 | 189 | 3.76 | 59.9 | 192.0 | 79 | 3.21 | 54.8 | 116.0 | 53 | 2.12 | 53.2 | 100.0 | 42 | 1.88 | 59.8 | 119.0 | 50 | 1.99 | 50.0 | 117.0 | 48 | 2.34 | 91.7 | 563.0 | 254 | 6.14 | 157.8 | 1098.0 | 527 | 6.96 | 236.5 | 1489.0 | 716 | 6.30 | ||||||||||||
2429 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2019 | 190 | 2 | 558.0 | 3225.0 | 1560 | 5.78 | 57.0 | 151.0 | 51 | 2.65 | 77.0 | 399.0 | 179 | 5.18 | 170.0 | 1160.0 | 603 | 6.82 | 254.0 | 1515.0 | 727 | 5.96 |
NR | 2429 |
Username | DerEkkat |
Einbaujahr der WP | 2017-12-01 |
PLZ des Wohnortes | 31167 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F1255-6 PC |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.8 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 190 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | Nein |
Bemerkungen | RGK |