Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2434 | Luft/Wasser | Nibe - F750 | 6.0 | 2023 | 140 | 4 | 3434.0 | 10079.0 | 2.94 | 591.0 | 2057.0 | 3.48 | 529.0 | 1513.0 | 2.86 | 405.0 | 1079.0 | 2.66 | 328.0 | 841.0 | 2.56 | 105.0 | 260.0 | 2.48 | 79.0 | 203.0 | 2.57 | 64.0 | 134.0 | 2.09 | 107.0 | 107.0 | 1.00 | 63.0 | 195.0 | 3.10 | 220.0 | 418.0 | 1.90 | 340.0 | 1229.0 | 3.61 | 603.0 | 2043.0 | 3.39 | |||||||||||||||||||||||||
2434 | Luft/Wasser | Nibe - F750 | 6.0 | 2022 | 140 | 4 | 2887.0 | 9933.0 | 3.44 | 527.0 | 2117.0 | 4.02 | 423.0 | 1579.0 | 3.73 | 340.0 | 1107.0 | 3.26 | 253.0 | 746.0 | 2.95 | 99.0 | 221.0 | 2.23 | 59.0 | 122.0 | 2.07 | 59.0 | 143.0 | 2.42 | 56.0 | 115.0 | 2.05 | 62.0 | 133.0 | 2.15 | 140.0 | 400.0 | 2.86 | 284.0 | 1187.0 | 4.18 | 585.0 | 2063.0 | 3.53 | |||||||||||||||||||||||||
2434 | Luft/Wasser | Nibe - F750 | 6.0 | 2021 | 140 | 4 | 3625.0 | 11975.0 | 3.30 | 684.0 | 2331.0 | 3.41 | 517.0 | 1721.0 | 3.33 | 413.0 | 1469.0 | 3.56 | 265.0 | 827.0 | 3.12 | 129.0 | 299.0 | 2.32 | 73.0 | 181.0 | 2.48 | 73.0 | 186.0 | 2.55 | 44.0 | 101.0 | 2.30 | 55.0 | 114.0 | 2.07 | 224.0 | 762.0 | 3.40 | 537.0 | 2025.0 | 3.77 | 611.0 | 1959.0 | 3.21 | |||||||||||||||||||||||||
2434 | Luft/Wasser | Nibe - F750 | 6.0 | 2020 | 140 | 4 | 3182.0 | 10708.0 | 3.37 | 570.0 | 1996.0 | 3.50 | 436.0 | 1582.0 | 3.63 | 357.0 | 1244.0 | 3.48 | 146.0 | 384.0 | 2.63 | 94.0 | 192.0 | 2.04 | 71.0 | 187.0 | 2.63 | 82.0 | 198.0 | 2.41 | 53.0 | 107.0 | 2.02 | 86.0 | 211.0 | 2.45 | 258.0 | 927.0 | 3.59 | 413.0 | 1511.0 | 3.66 | 616.0 | 2169.0 | 3.52 | |||||||||||||||||||||||||
2434 | Luft/Wasser | Nibe - F750 | 6.0 | 2019 | 140 | 4 | 1414.0 | 4506.0 | 3.32 | 55.0 | 0 | 0 | 64.0 | 85.0 | 0 | 1.33 | 80.0 | 103.0 | 0 | 1.29 | 240.0 | 814.0 | 3.39 | 437.0 | 1640.0 | 3.75 | 538.0 | 1864.0 | 3.46 |
NR | 2434 |
Username | Heater910 |
Einbaujahr der WP | 2019-06-30 |
PLZ des Wohnortes | 91056 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe - F750 |
modulierend | |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 40.8 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 52 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Abluft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2800 Watt DB |
elektr. Verbrauch HP gem./DB | 260 Watt |
elektr. Verbrauch WQ P gem./DB | 260 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 19.5 °C |
Heizung max. Vorlauf Temp. | 38.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 140 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Permanent Lüftungsanlage über Stromzähler der WP. Eine externe regelbare Außenluftzufuhr direkt zur WP. (Außenluft gefiltert aber nicht vorerwärmt) |