Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2438 | Luft/Wasser | Stiebel Eltron LWZ 5 CS Premium | 5.5 | 2025 | 190 | 3 | 3451.0 | 12900.0 | 2858 | 3.74 | 844.0 | 2800.0 | 615 | 3.32 | 192.0 | 700.0 | 180 | 3.65 | 446.0 | 1600.0 | 402 | 3.59 | 255.0 | 1100.0 | 212 | 4.31 | 128.0 | 500.0 | 54 | 3.91 | 114.0 | 500.0 | 52 | 4.39 | 85.0 | 300.0 | 58 | 3.53 | 102.0 | 400.0 | 61 | 3.92 | 150.0 | 500.0 | 104 | 3.33 | 245.0 | 1000.0 | 229 | 4.08 | 422.0 | 1900.0 | 450 | 4.50 | 468.0 | 1600.0 | 441 | 3.42 | ||||||||||||
| 2438 | Luft/Wasser | Stiebel Eltron LWZ 5 CS Premium | 5.5 | 2024 | 190 | 3 | 3392.0 | 12700.0 | 2862 | 3.74 | 628.0 | 2100.0 | 512 | 3.34 | 345.0 | 1400.0 | 375 | 4.06 | 290.0 | 1400.0 | 324 | 4.83 | 295.0 | 1000.0 | 239 | 3.39 | 138.0 | 600.0 | 71 | 4.35 | 125.0 | 300.0 | 55 | 2.40 | 113.0 | 500.0 | 47 | 4.42 | 103.0 | 300.0 | 41 | 2.91 | 131.0 | 500.0 | 63 | 3.82 | 232.0 | 800.0 | 192 | 3.45 | 397.0 | 1700.0 | 411 | 4.28 | 595.0 | 2100.0 | 532 | 3.53 | ||||||||||||
| 2438 | Luft/Wasser | Stiebel Eltron LWZ 5 CS Premium | 5.5 | 2023 | 190 | 3 | 3066.0 | 12000.0 | 2715 | 3.91 | 475.0 | 1800.0 | 469 | 3.79 | 418.0 | 1600.0 | 414 | 3.83 | 379.0 | 1500.0 | 372 | 3.96 | 276.0 | 1100.0 | 261 | 3.99 | 147.0 | 600.0 | 88 | 4.08 | 77.0 | 300.0 | 24 | 3.90 | 83.0 | 300.0 | 32 | 3.61 | 103.0 | 300.0 | 36 | 2.91 | 89.0 | 400.0 | 31 | 4.49 | 168.0 | 700.0 | 121 | 4.17 | 361.0 | 1400.0 | 357 | 3.88 | 490.0 | 2000.0 | 510 | 4.08 | ||||||||||||
| 2438 | Luft/Wasser | Stiebel Eltron LWZ 5 CS Premium | 5.5 | 2022 | 190 | 3 | 3218.0 | 12600.0 | 2334 | 3.92 | 553.0 | 2100.0 | 3.80 | 370.0 | 1400.0 | 394 | 3.78 | 355.0 | 1500.0 | 338 | 4.23 | 289.0 | 1100.0 | 271 | 3.81 | 118.0 | 400.0 | 64 | 3.39 | 107.0 | 400.0 | 50 | 3.74 | 114.0 | 500.0 | 56 | 4.39 | 104.0 | 400.0 | 43 | 3.85 | 128.0 | 600.0 | 90 | 4.69 | 182.0 | 800.0 | 145 | 4.40 | 318.0 | 1300.0 | 346 | 4.09 | 580.0 | 2100.0 | 537 | 3.62 | |||||||||||||
| 2438 | Luft/Wasser | Stiebel Eltron LWZ 5 CS Premium | 5.5 | 2021 | 190 | 2 | 4304.0 | 754.0 | 656.0 | 524.0 | 385.0 | 240.0 | 100.0 | 102.0 | 119.0 | 120.0 | 282.0 | 460.0 | 562.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
| 2438 | Luft/Wasser | Stiebel Eltron LWZ 5 CS Premium | 5.5 | 2020 | 190 | 2 | 4744.0 | 1041.0 | 705.0 | 618.0 | 242.0 | 193.0 | 117.0 | 120.0 | 105.0 | 143.0 | 308.0 | 525.0 | 627.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
| 2438 | Luft/Wasser | Stiebel Eltron LWZ 5 CS Premium | 5.5 | 2019 | 190 | 2 | 2750.0 | 778.0 | 747.0 | 1225.0 |
| NR | 2438 |
| Username | basti1984 |
| Einbaujahr der WP | 2019-10-09 |
| PLZ des Wohnortes | 64560 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Stiebel Eltron LWZ 5 CS Premium |
| modulierend | Ja |
| Leistung (0/35) | 5.5 kW |
| berechneter Primärenergiebedarf | 29.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 49 °C |
| WW Legionellenschaltung | Ja |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 0.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 190 m² |
| Lüftung | zenKWLWR |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Verbrauchswerte am Stromzähler HT+NT abgelesen, Verbrauch der kompletten Anlage inkl. Steuerung, Heizung, Warmwasser und Lüftungsanlage. Haus Neubau 2019, KfW55 defektes Umschaltventil seit Sommer 2020, Reparatur zum 30.04.2021. Daher erhöhter Verbrauch. |