Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2501 | Luft/Wasser | Buderus WLW196i-6 AR | 7.6 | 2023 | 185 | 3 | 3544.0 | 5689.0 | 1898 | 1.61 | 1225.0 | 1693.0 | 549 | 1.38 | 1589.0 | 968.0 | 299 | 0.61 | 429.0 | 1707.0 | 566 | 3.98 | 301.0 | 1321.0 | 484 | 4.39 | ||||||||||||||||||||||||||||||||||||||||||||
2501 | Luft/Wasser | Buderus WLW196i-6 AR | 7.6 | 2022 | 185 | 2 | 4008.0 | 14593.0 | 4428 | 3.64 | 813.0 | 2610.0 | 697 | 3.21 | 524.0 | 1949.0 | 591 | 3.72 | 558.0 | 1929.0 | 564 | 3.46 | 360.0 | 1416.0 | 456 | 3.93 | 127.0 | 536.0 | 164 | 4.22 | 76.0 | 260.0 | 69 | 3.42 | 69.0 | 223.0 | 52 | 3.23 | 67.0 | 251.0 | 60 | 3.75 | 156.0 | 750.0 | 258 | 4.81 | 149.0 | 762.0 | 259 | 5.11 | 357.0 | 1541.0 | 569 | 4.32 | 752.0 | 2366.0 | 689 | 3.15 | ||||||||||||
2501 | Luft/Wasser | Buderus WLW196i-6 AR | 7.6 | 2021 | 185 | 2 | 4840.0 | 16384.0 | 4922 | 3.39 | 1043.0 | 2671.0 | 697 | 2.56 | 646.0 | 1918.0 | 577 | 2.97 | 559.0 | 1987.0 | 603 | 3.55 | 400.0 | 1490.0 | 481 | 3.73 | 213.0 | 984.0 | 355 | 4.62 | 82.0 | 310.0 | 76 | 3.78 | 78.0 | 326.0 | 77 | 4.18 | 74.0 | 325.0 | 88 | 4.39 | 97.0 | 441.0 | 136 | 4.55 | 279.0 | 1252.0 | 455 | 4.49 | 613.0 | 2205.0 | 668 | 3.60 | 756.0 | 2475.0 | 709 | 3.27 | ||||||||||||
2501 | Luft/Wasser | Buderus WLW196i-6 AR | 7.6 | 2020 | 185 | 2 | 4357.0 | 14759.0 | 4526 | 3.39 | 738.0 | 2315.0 | 673 | 3.14 | 520.0 | 1844.0 | 557 | 3.55 | 509.0 | 1772.0 | 559 | 3.48 | 228.0 | 865.0 | 294 | 3.79 | 193.0 | 792.0 | 276 | 4.10 | 120.0 | 511.0 | 151 | 4.26 | 110.0 | 309.0 | 75 | 2.81 | 82.0 | 292.0 | 61 | 3.56 | 120.0 | 474.0 | 145 | 3.95 | 295.0 | 1281.0 | 476 | 4.34 | 555.0 | 1854.0 | 604 | 3.34 | 887.0 | 2450.0 | 655 | 2.76 | ||||||||||||
2501 | Luft/Wasser | Buderus WLW196i-6 AR | 7.6 | 2019 | 185 | 2 | 3428.0 | 10789.0 | 3337 | 3.15 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 3428.0 | 10789.0 | 3337 | 3.15 |
NR | 2501 |
Username | Monte1977 |
Einbaujahr der WP | 2019-03-10 |
PLZ des Wohnortes | 86853 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Buderus WLW196i-6 AR |
modulierend | |
Leistung (0/35) | 7.6 kW |
berechneter Primärenergiebedarf | 31.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 54 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: |
WMZ | intern |
Mittlere Raumtemp. | 23 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 185 m² |
Lüftung | zenKWL |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | 01/02-2023 Ventilator WP defekt, ca. 20 Tage ausschließlicher Betrieb mittels Heizstab |