Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2525 | Luft/Wasser | Alpha Innotec LWDV 91-1/3 | 8.2 | 2024 | 144 | 6 | 1636.0 | 5927.0 | 1493 | 3.62 | 483.0 | 1896.0 | 513 | 3.93 | 284.0 | 1139.0 | 310 | 4.01 | 240.0 | 943.0 | 262 | 3.93 | 201.0 | 753.0 | 202 | 3.75 | 98.0 | 292.0 | 52 | 2.98 | 88.0 | 249.0 | 40 | 2.83 | 81.0 | 228.0 | 38 | 2.81 | 69.0 | 167.0 | 27 | 2.42 | 92.0 | 260.0 | 49 | 2.83 | ||||||||||||||||||||||||
2525 | Luft/Wasser | Alpha Innotec LWDV 91-1/3 | 8.2 | 2023 | 144 | 6 | 2735.0 | 9029.0 | 2378 | 3.30 | 427.0 | 1479.0 | 403 | 3.46 | 393.0 | 1365.0 | 412 | 3.47 | 310.0 | 1105.0 | 293 | 3.56 | 243.0 | 887.0 | 243 | 3.65 | 143.0 | 366.0 | 61 | 2.56 | 92.0 | 211.0 | 33 | 2.29 | 97.0 | 209.0 | 34 | 2.15 | 92.0 | 188.0 | 28 | 2.04 | 83.0 | 203.0 | 33 | 2.45 | 128.0 | 385.0 | 87 | 3.01 | 374.0 | 1341.0 | 380 | 3.59 | 353.0 | 1290.0 | 371 | 3.65 | ||||||||||||
2525 | Luft/Wasser | Alpha Innotec LWDV 91-1/3 | 8.2 | 2022 | 144 | 6 | 3227.0 | 10140.0 | 2107 | 3.14 | 587.0 | 1883.0 | 449 | 3.21 | 379.0 | 1287.0 | 298 | 3.40 | 378.0 | 1166.0 | 255 | 3.08 | 302.0 | 979.0 | 211 | 3.24 | 144.0 | 422.0 | 66 | 2.93 | 117.0 | 335.0 | 48 | 2.86 | 105.0 | 306.0 | 46 | 2.91 | 91.0 | 261.0 | 39 | 2.87 | 134.0 | 384.0 | 63 | 2.87 | 180.0 | 539.0 | 89 | 2.99 | 323.0 | 1050.0 | 214 | 3.25 | 487.0 | 1528.0 | 329 | 3.14 | ||||||||||||
2525 | Luft/Wasser | Alpha Innotec LWDV 91-1/3 | 8.2 | 2021 | 144 | 5 | 4001.0 | 12961.0 | 2753 | 3.24 | 740.0 | 2400.0 | 506 | 3.24 | 445.0 | 1446.0 | 394 | 3.25 | 438.0 | 1444.0 | 331 | 3.30 | 335.0 | 1062.0 | 244 | 3.17 | 221.0 | 715.0 | 147 | 3.24 | 112.0 | 303.0 | 45 | 2.71 | 117.0 | 333.0 | 45 | 2.85 | 127.0 | 369.0 | 61 | 2.91 | 143.0 | 431.0 | 76 | 3.01 | 264.0 | 879.0 | 187 | 3.33 | 447.0 | 1516.0 | 339 | 3.39 | 612.0 | 2063.0 | 378 | 3.37 | ||||||||||||
2525 | Luft/Wasser | Alpha Innotec LWDV 91-1/3 | 8.2 | 2020 | 144 | 5 | 3837.7 | 11958.8 | 2513 | 3.12 | 738.0 | 1762.0 | 363 | 2.39 | 633.0 | 2156.0 | 470 | 3.41 | 326.0 | 1045.0 | 215 | 3.21 | 210.0 | 662.0 | 120 | 3.15 | 143.0 | 397.0 | 59 | 2.78 | 116.0 | 362.0 | 53 | 3.12 | 113.7 | 352.8 | 54 | 3.10 | 155.0 | 474.0 | 83 | 3.06 | 302.0 | 979.0 | 251 | 3.24 | 502.0 | 1726.0 | 391 | 3.44 | 599.0 | 2043.0 | 454 | 3.41 |
NR | 2525 |
Username | Matthias |
Einbaujahr der WP | 2019-11-01 |
PLZ des Wohnortes | 90518 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Alpha Innotec LWDV 91-1/3 |
modulierend | Ja |
Leistung (0/35) | 8.2 kW |
berechneter Primärenergiebedarf | 29.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 55 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 144 m² |
Lüftung | zenKWLWR |
Personen | 6 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | LWDV + HSDV 9M 1/3, Nutzfläche 214m², KFW 55, Raumtemperatur ca. 22-23°C, Warmwasser über Wärmepumpe für 6 Personen, zentrale Be- und Entlüftung, große Fensterfläche im EG, EVU-Sperre 4h/Tag wodurch Verbrauch erhöht und AZ verschlechtert wird. Große Probleme zu Beginn wg. permanenter Vereisung u.a. aufgrund defekten Inverters. Seit 2023 Hysterese von Heizung von 2K auf 1K und Warmwasser von 2K auf 10K verändert. Seit 2024 läuft die Anlage 24/7 im Silent-Mode, Überstromventil zu, Bodenventile stromlos offen, ERR aus, dadurch deutlich verbesserte Effizienz der Anlage. |