Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2546 | Luft/Wasser | Daikin Altherma 3 R ECH2O 508 | 8.0 | 2022 | 194 | 4 | 1605.0 | 6903.0 | 1949 | 4.30 | 628.0 | 2606.0 | 708 | 4.15 | 542.0 | 2358.0 | 670 | 4.35 | 435.0 | 1939.0 | 571 | 4.46 | ||||||||||||||||||||||||||||||||||||||||||||||||
2546 | Luft/Wasser | Daikin Altherma 3 R ECH2O 508 | 8.0 | 2021 | 194 | 4 | 3870.0 | 16831.0 | 5258 | 4.35 | 770.0 | 2894.0 | 697 | 3.76 | 546.0 | 2309.0 | 635 | 4.23 | 430.0 | 2014.0 | 632 | 4.68 | 227.0 | 1080.0 | 410 | 4.76 | 237.0 | 1308.0 | 547 | 5.52 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 152.0 | 826.0 | 414 | 5.43 | 308.0 | 1471.0 | 553 | 4.78 | 538.0 | 2374.0 | 702 | 4.41 | 662.0 | 2555.0 | 668 | 3.86 | |||||||||||||||
2546 | Luft/Wasser | Daikin Altherma 3 R ECH2O 508 | 8.0 | 2020 | 194 | 4 | 3744.0 | 15927.0 | 5014 | 4.25 | 741.0 | 2862.0 | 637 | 3.86 | 466.0 | 2300.0 | 586 | 4.94 | 457.0 | 1472.0 | 650 | 3.22 | 227.0 | 1073.0 | 400 | 4.73 | 177.0 | 1006.0 | 456 | 5.68 | 60.0 | 346.0 | 158 | 5.77 | 0 | 0 | 0 | 0 | 0 | 0 | 123.0 | 644.0 | 300 | 5.24 | 286.0 | 1430.0 | 532 | 5.00 | 514.0 | 2124.0 | 614 | 4.13 | 693.0 | 2670.0 | 681 | 3.85 | ||||||||||||||
2546 | Luft/Wasser | Daikin Altherma 3 R ECH2O 508 | 8.0 | 2019 | 194 | 4 | 1880.0 | 10084.0 | 3018 | 5.36 | 236.0 | 1431.0 | 232 | 6.06 | 248.0 | 1357.0 | 558 | 5.47 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 142.0 | 793.0 | 332 | 5.58 | 257.0 | 1517.0 | 638 | 5.90 | 417.0 | 2186.0 | 622 | 5.24 | 580.0 | 2800.0 | 636 | 4.83 |
NR | 2546 |
Username | wysel |
Einbaujahr der WP | 2019-04-01 |
PLZ des Wohnortes | A-8184 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Daikin Altherma 3 R ECH2O 508 |
modulierend | Ja |
Leistung (0/35) | 8.0 kW |
berechneter Primärenergiebedarf | 47.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 0.3 |
Heizflaeche | 194 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Generalsaniertes EFH aus den 1960ern, Schattenseite, 194m²= Brutto-Grundfläche |