Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2585 | Luft/Wasser | Vaillant arotherm Split VWL 755 AS | 4.6 | 2026 | 130 | 4 | 792.0 | 3200.0* | 650 | 4.04 | 792.0 | 2920.0 | 650 | 4.04 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2585 | Luft/Wasser | Vaillant arotherm Split VWL 755 AS | 4.6 | 2025 | 130 | 4 | 3847.0 | * | 7691 | 637.0 | 650 | 640.0 | 621 | 451.0 | 650 | 258.0 | 630 | 207.0 | 650 | 74.0 | 630 | 72.0 | 650 | 75.0 | 650 | 125.0 | 630 | 264.0 | 650 | 455.0 | 630 | 589.0 | 650 | |||||||||||||||||||||||||||||||||||||
| 2585 | Luft/Wasser | Vaillant arotherm Split VWL 755 AS | 4.6 | 2024 | 130 | 4 | 3467.0 | * | 7691 | 741.0 | 650 | 389.0 | 621 | 374.0 | 650 | 251.0 | 630 | 121.0 | 650 | 90.0 | 630 | 60.0 | 650 | 50.0 | 650 | 112.0 | 630 | 229.0 | 650 | 459.0 | 630 | 591.0 | 650 | |||||||||||||||||||||||||||||||||||||
| 2585 | Luft/Wasser | Vaillant arotherm Split VWL 755 AS | 4.6 | 2023 | 130 | 3 | 3495.0 | * | 7691 | 523.0 | 650 | 541.0 | 621 | 487.0 | 650 | 379.0 | 630 | 174.0 | 650 | 77.0 | 630 | 58.0 | 650 | 58.0 | 650 | 84.0 | 630 | 185.0 | 650 | 398.0 | 630 | 531.0 | 650 | |||||||||||||||||||||||||||||||||||||
| 2585 | Luft/Wasser | Vaillant arotherm Split VWL 755 AS | 4.6 | 2022 | 130 | 3 | 3723.0 | * | 7691 | 652.0 | 650 | 463.0 | 621 | 514.0 | 650 | 376.0 | 630 | 146.0 | 650 | 76.0 | 630 | 65.0 | 650 | 52.0 | 650 | 143.0 | 630 | 183.0 | 650 | 380.0 | 630 | 673.0 | 650 | |||||||||||||||||||||||||||||||||||||
| 2585 | Luft/Wasser | Vaillant arotherm Split VWL 755 AS | 4.6 | 2021 | 130 | 3 | 5274.0 | * | 7711 | 1014.0 | 650 | 1162.0 | 621 | 580.0 | 650 | 458.0 | 650 | 243.0 | 650 | 69.0 | 630 | 57.0 | 650 | 82.0 | 650 | 108.0 | 630 | 338.0 | 650 | 467.0 | 630 | 696.0 | 650 | |||||||||||||||||||||||||||||||||||||
| 2585 | Luft/Wasser | Vaillant arotherm Split VWL 755 AS | 4.6 | 2020 | 130 | 2 | 1397.0 | * | 3860 | 69.0 | 650 | 47.0 | 650 | 85.0 | 630 | 236.0 | 650 | 392.0 | 630 | 568.0 | 650 |
| NR | 2585 |
| Username | ToFoe |
| Einbaujahr der WP | 2020-03-21 |
| PLZ des Wohnortes | 01909 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Vaillant arotherm Split VWL 755 AS |
| modulierend | Ja |
| Leistung (0/35) | 4.6 kW |
| berechneter Primärenergiebedarf | 34.1 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 50 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | > erfasst: |
| WMZ | |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 0.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 130 m² |
| Lüftung | Fenster |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | mit uniTower 785 IS |