Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2025 | 153 | 3 | 1808.0 | 513 | 823.0 | 235 | 615.0 | 176 | 370.0 | 102 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2024 | 153 | 2 | 3039.0 | 867 | 750.0 | 214 | 515.0 | 147 | 329.0 | 94 | 189.0 | 53 | 0 | 0 | 0 | 0 | 0 | 52.0 | 15 | 360.0 | 103 | 844.0 | 241 | |||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2023 | 153 | 2 | 3272.0 | 935 | 605.0 | 173 | 547.0 | 156 | 546.0 | 156 | 364.0 | 104 | 23.0 | 6 | 0 | 0 | 0 | 0 | 184.0 | 53 | 353.0 | 101 | 650.0 | 186 | ||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2022 | 153 | 2 | 3095.0 | 887 | 659.0 | 188 | 590.0 | 169 | 417.0 | 121 | 297.0 | 85 | 18.0 | 5 | 0 | 0 | 0 | 59.0 | 17 | 52.0 | 15 | 353.0 | 101 | 650.0 | 186 | |||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2021 | 153 | 2 | 3752.0 | 1073 | 744.0 | 213 | 618.0 | 177 | 534.0 | 152 | 412.0 | 119 | 115.0 | 32 | 0 | 0 | 0 | 0 | 250.0 | 71 | 436.0 | 125 | 643.0 | 184 | ||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2020 | 153 | 2 | 3065.0 | 873 | 630.0 | 180 | 593.0 | 170 | 400.0 | 114 | 156.0 | 44 | 94.0 | 26 | 0 | 0 | 0 | 0 | 225.0 | 63 | 367.0 | 105 | 600.0 | 171 | ||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2019 | 153 | 2 | 3640.0 | 1038 | 880.0 | 251 | 595.0 | 170 | 514.0 | 147 | 203.0 | 58 | 125.0 | 35 | 0 | 0 | 0 | 0 | 222.0 | 63 | 517.0 | 148 | 584.0 | 166 | ||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2018 | 153 | 2 | 3538.0 | 1010 | 700.0 | 200 | 651.0 | 186 | 675.0 | 193 | 91.0 | 25 | 0 | 0 | 0 | 0 | 0 | 319.0 | 91 | 469.0 | 134 | 633.0 | 181 | |||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2017 | 153 | 2 | 3922.0 | 1120 | 804.0 | 230 | 790.0 | 226 | 440.0 | 126 | 250.0 | 71 | 79.0 | 23 | 0 | 0 | 0 | 0 | 215.0 | 61 | 452.0 | 129 | 892.0 | 254 | ||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2016 | 153 | 2 | 3516.0 | 1004 | 767.0 | 219 | 698.0 | 199 | 540.0 | 154 | 163.0 | 47 | 0 | 0 | 0 | 0 | 0 | 265.0 | 76 | 490.0 | 140 | 593.0 | 169 | |||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2015 | 153 | 2 | 3136.0 | 895 | 769.0 | 220 | 651.0 | 186 | 498.0 | 142 | 176.0 | 50 | 40.0 | 11 | 0 | 0 | 0 | 0 | 235.0 | 67 | 349.0 | 100 | 418.0 | 119 | ||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2014 | 153 | 4 | 2994.0 | 855 | 671.0 | 192 | 605.0 | 173 | 362.0 | 103 | 58.0 | 17 | 186.0 | 53 | 0 | 0 | 0 | 0 | 81.0 | 23 | 341.0 | 97 | 690.0 | 197 | ||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2013 | 153 | 4 | 3643.0 | 1039 | 806.0 | 230 | 692.0 | 198 | 759.0 | 214 | 273.0 | 78 | 58.0 | 17 | 0 | 0 | 0 | 0 | 151.0 | 43 | 433.0 | 124 | 471.0 | 135 | ||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2012 | 153 | 4 | 3696.0 | 1057 | 797.0 | 227 | 937.0 | 268 | 329.0 | 94 | 324.0 | 93 | 79.0 | 23 | 0 | 0 | 0 | 0 | 181.0 | 52 | 420.0 | 120 | 629.0 | 180 | ||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2011 | 153 | 4 | 3687.0 | 1053 | 871.0 | 249 | 767.0 | 219 | 604.0 | 173 | 75.0 | 21 | 0 | 0 | 0 | 0 | 0 | 180.0 | 51 | 443.0 | 127 | 747.0 | 213 | |||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2010 | 153 | 4 | 5035.0 | 1077.0 | 887.0 | 665.0 | 267.0 | 223.0 | 0 | 0 | 0 | 26.0 | 264.0 | 548.0 | 1078.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
260 | Sole/Wasser | KFR Kälte Fedder | 15.2 | 2009 | 153 | 4 | 4666.0 | 1090.0 | 982.0 | 837.0 | 101.0 | 22.0 | 0 | 0 | 0 | 0 | 351.0 | 464.0 | 819.0 |
NR | 260 |
Username | rokra |
Einbaujahr der WP | 2006-09-01 |
PLZ des Wohnortes | 308xx |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | KFR Kälte Fedder |
modulierend | Nein |
Leistung (0/35) | 15.2 kW |
berechneter Primärenergiebedarf | 100.0 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 0 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.7 m |
Fläche | 350 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2970 Watt DB |
elektr. Verbrauch HP gem./DB | 40 Watt |
elektr. Verbrauch WQ P gem./DB | 112 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 9.0 |
Heizflaeche | 153 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | WP ohne Außenfühler, mittels Zeitschaltuhr, Primärenergiebedarf geschätzt, da kein Wert vorhanden, Erstgerät Waterkotte von 1982,ab 2006 Fedder,Stromverbrauch WP ca. 67%NT 33%HT, Betriebsstunden manuell ermittelt(Kwh:3,5 Komp./Pumpen) BWP ca. 700 Kwh/NT jährl., |