Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2603 | Wasser/Wasser | NIBE S1155PC-6 | 9.3 | 2023 | 200 | 6 | 2149.0 | 10602.0 | 2617 | 4.93 | 709.0 | 3589.0 | 744 | 5.06 | 607.0 | 2928.0 | 635 | 4.82 | 463.0 | 2268.0 | 653 | 4.90 | 370.0 | 1817.0 | 585 | 4.91 | ||||||||||||||||||||||||||||||||||||||||||||
2603 | Wasser/Wasser | NIBE S1155PC-6 | 9.3 | 2022 | 200 | 6 | 3994.0 | 19522.0 | 4965 | 4.95 | 784.0 | 3935.0 | 752 | 5.02 | 605.0 | 3037.0 | 752 | 5.02 | 491.0 | 2403.0 | 628 | 4.89 | 366.0 | 1811.0 | 542 | 4.95 | 113.0 | 416.0 | 171 | 3.68 | 49.0 | 48.0 | 18 | 0.98 | 63.0 | 61.0 | 25 | 0.97 | 49.0 | 0 | 0 | 149.0 | 744.0 | 297 | 4.99 | 186.0 | 923.0 | 366 | 4.96 | 438.0 | 2521.0 | 703 | 5.76 | 701.0 | 3623.0 | 711 | 5.17 | |||||||||||||
2603 | Wasser/Wasser | NIBE S1155PC-6 | 9.3 | 2021 | 200 | 6 | 5022.0 | 25325.0 | 5427 | 5.04 | 917.0 | 4423.0 | 729 | 4.82 | 673.0 | 3123.0 | 601 | 4.64 | 587.0 | 2927.0 | 651 | 4.99 | 434.0 | 2246.0 | 528 | 5.18 | 354.0 | 1712.0 | 505 | 4.84 | 76.0 | 111.0 | 39 | 1.46 | 81.0 | 124.0 | 1 | 1.53 | 96.0 | 461.0 | 169 | 4.80 | 97.0 | 542.0 | 164 | 5.59 | 332.0 | 2181.0 | 590 | 6.57 | 614.0 | 3542.0 | 711 | 5.77 | 761.0 | 3933.0 | 739 | 5.17 | ||||||||||||
2603 | Wasser/Wasser | NIBE S1155PC-6 | 9.3 | 2020 | 200 | 6 | 1731.0 | 9255.0 | 2183 | 5.35 | 115.0 | 558.0 | 127 | 4.85 | 327.0 | 1896.0 | 647 | 5.80 | 516.0 | 2848.0 | 664 | 5.52 | 773.0 | 3953.0 | 745 | 5.11 |
NR | 2603 |
Username | passra |
Einbaujahr der WP | 2020-08-01 |
PLZ des Wohnortes | 84036 |
Bauart | Wasser/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | NIBE S1155PC-6 |
modulierend | Ja |
Leistung (0/35) | 9.3 kW |
berechneter Primärenergiebedarf | 125.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Förder- und Schluckbrunnen |
Tiefe | 2.7 m |
Fläche | 0 m² |
Heizungsart | Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 2000 Watt DB |
elektr. Verbrauch HP gem./DB | 25 Watt |
elektr. Verbrauch WQ P gem./DB | 25 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern |
Mittlere Raumtemp. | 23 °C |
Mittlere Wärmequellentemperatur | 10.0 °C |
Heizung max. Vorlauf Temp. | 50.0 °C |
Spreizung Heizkr. | 7.0 |
Heizflaeche | 200 m² |
Lüftung | zenKWLWR |
Personen | 6 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Förderung Grundwasser im Saugheberprinzip mit durchschnittlich 19W für 2000l/h 10m² Solar; 1600l Bestandspuffer für WW und Heizungsunterstützung |