Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2628 | Luft/Wasser | Daikin Altherma 3 R ECH2O 308 | 6.0 | 2023 | 130 | 3 | 1051.0 | 4966.0 | 1668 | 4.73 | 385.0 | 1814.0 | 624 | 4.71 | 345.0 | 1608.0 | 524 | 4.66 | 321.0 | 1544.0 | 520 | 4.81 | ||||||||||||||||||||||||||||||||||||||||||||||||
| 2628 | Luft/Wasser | Daikin Altherma 3 R ECH2O 308 | 6.0 | 2022 | 130 | 3 | 2732.0 | 12662.0 | 4078 | 4.74 | 402.0 | 1974.0 | 619 | 4.91 | 326.0 | 1616.0 | 523 | 4.96 | 345.0 | 1592.0 | 524 | 4.61 | 231.0 | 1143.0 | 391 | 4.95 | 87.0 | 330.0 | 95 | 3.79 | 62.0 | 96.0 | 483.0 | 137 | 5.03 | 103.0 | 604.0 | 174 | 5.86 | 103.0 | 522.0 | 176 | 5.07 | 156.0 | 822.0 | 319 | 5.27 | 321.0 | 1520.0 | 504 | 4.74 | 500.0 | 2056.0 | 616 | 4.11 | |||||||||||||||
| 2628 | Luft/Wasser | Daikin Altherma 3 R ECH2O 308 | 6.0 | 2021 | 130 | 3 | 3146.0 | 13717.0 | 4230 | 4.36 | 543.0 | 2486.0 | 660 | 4.58 | 609.0 | 2082.0 | 547 | 3.42 | 345.0 | 1695.0 | 523 | 4.91 | 263.0 | 1322.0 | 449 | 5.03 | 144.0 | 688.0 | 252 | 4.78 | 54.0 | 134.0 | 22 | 2.48 | 41.0 | 129.0 | 21 | 3.15 | 42.0 | 130.0 | 21 | 3.10 | 112.0 | 424.0 | 112 | 3.79 | 207.0 | 1089.0 | 427 | 5.26 | 313.0 | 1347.0 | 563 | 4.30 | 473.0 | 2191.0 | 633 | 4.63 | ||||||||||||
| 2628 | Luft/Wasser | Daikin Altherma 3 R ECH2O 308 | 6.0 | 2020 | 130 | 3 | 769.0 | 4120.0 | 1207 | 5.36 | 334.0 | 1858.0 | 622 | 5.56 | 435.0 | 2262.0 | 585 | 5.20 |
| NR | 2628 |
| Username | Mogul |
| Einbaujahr der WP | 2020-10-09 |
| PLZ des Wohnortes | 06526 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Daikin Altherma 3 R ECH2O 308 |
| modulierend | Ja |
| Leistung (0/35) | 6.0 kW |
| berechneter Primärenergiebedarf | 49.7 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 48 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 45.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 130 m² |
| Lüftung | Fenster |
| Personen | 3 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | ab 04/21 Erhöhrung der WW-Temperatur auf 48 °C bei 5 °C Hysterese, ab 28.06.22 wurde im Sommer die Kühlfunktion genutzt, AZ daher ungenau für WW + Kühlen, |