Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2659 | Luft/Wasser | AIT LWD50A | 5.0 | 2023 | 171 | 3 | 2094.0 | 5703.0 | 2.72 | 398.0 | 1322.0 | 3.32 | 335.0 | 1108.0 | 3.31 | 305.0 | 985.0 | 3.23 | 238.0 | 735.0 | 3.09 | 191.0 | 334.0 | 1.75 | 95.0 | 241.0 | 2.54 | 85.0 | 238.0 | 2.80 | 93.0 | 129.0 | 1.39 | 183.0 | 126.0 | 0.69 | 171.0 | 485.0 | 2.84 | |||||||||||||||||||||||||||||||
| 2659 | Luft/Wasser | AIT LWD50A | 5.0 | 2022 | 171 | 3 | 1016.0 | 3827.0 | 653 | 3.77 | 337.0 | 1248.0 | 226 | 3.70 | 260.0 | 992.0 | 168 | 3.82 | 254.0 | 976.0 | 159 | 3.84 | 165.0 | 611.0 | 100 | 3.70 | ||||||||||||||||||||||||||||||||||||||||||||
| 2659 | Luft/Wasser | AIT LWD50A | 5.0 | 2021 | 171 | 3 | 2707.0 | 9438.0 | 1300 | 3.49 | 461.0 | 1527.0 | 177 | 3.31 | 390.0 | 1224.0 | 245 | 3.14 | 329.0 | 1250.0 | 3.80 | 247.0 | 866.0 | 143 | 3.51 | 158.0 | 510.0 | 75 | 3.23 | 55.0 | 202.0 | 26 | 3.67 | 44.0 | 166.0 | 21 | 3.77 | 70.0 | 263.0 | 35 | 3.76 | 130.0 | 309.0 | 42 | 2.38 | 185.0 | 762.0 | 115 | 4.12 | 300.0 | 1143.0 | 196 | 3.81 | 338.0 | 1216.0 | 225 | 3.60 | |||||||||||||
| 2659 | Luft/Wasser | AIT LWD50A | 5.0 | 2020 | 171 | 2 | 377.5 | 1300.8 | 243 | 3.45 | 377.5 | 1300.8 | 243 | 3.45 |
| NR | 2659 |
| Username | TbsJah |
| Einbaujahr der WP | 2019-06-01 |
| PLZ des Wohnortes | 36364 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | AIT LWD50A |
| modulierend | Nein |
| Leistung (0/35) | 5.0 kW |
| berechneter Primärenergiebedarf | 6.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 50 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 1440 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 0.0 °C |
| Spreizung Heizkr. | 5.0 |
| Heizflaeche | 171 m² |
| Lüftung | zenKWLWR |
| Personen | 3 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |