Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2667 | Sole/Wasser | IDM iPump 2 - 8 | 7.9 | 2023 | 160 | 4 | 2042.0 | 9827.3 | 3029 | 4.81 | 344.0 | 1791.0 | 521 | 5.21 | 312.0 | 1691.0 | 486 | 5.42 | 271.0 | 1430.0 | 438 | 5.28 | 185.0 | 970.0 | 305 | 5.24 | 70.0 | 180.0 | 58 | 2.57 | 46.0 | 27.0 | 10 | 0.59 | 45.0 | 50.2 | 17 | 1.12 | 63.0 | 97.7 | 72 | 1.55 | 50.0 | 74.4 | 52 | 1.49 | 127.0 | 533.0 | 168 | 4.20 | 241.0 | 1256.0 | 389 | 5.21 | 288.0 | 1727.0 | 513 | 6.00 | ||||||||||||
2667 | Sole/Wasser | IDM iPump 2 - 8 | 7.9 | 2022 | 160 | 4 | 2144.0 | 10104.2 | 3206 | 4.71 | 394.0 | 2026.0 | 668 | 5.14 | 317.0 | 1687.0 | 550 | 5.32 | 272.0 | 1364.0 | 456 | 5.01 | 197.0 | 952.0 | 319 | 4.83 | 51.0 | 180.0 | 56 | 3.53 | 43.0 | 13.2 | 4 | 0.31 | 54.0 | 35.0 | 13 | 0.65 | 59.0 | 70.0 | 24 | 1.19 | 62.0 | 204.0 | 68 | 3.29 | 102.0 | 380.0 | 127 | 3.73 | 233.0 | 1274.0 | 386 | 5.47 | 360.0 | 1919.0 | 535 | 5.33 | ||||||||||||
2667 | Sole/Wasser | IDM iPump 2 - 8 | 7.9 | 2021 | 160 | 4 | 2823.1 | 13740.3 | 4225 | 4.87 | 511.2 | 2533.0 | 699 | 4.96 | 409.0 | 1879.0 | 530 | 4.59 | 373.9 | 1734.0 | 543 | 4.64 | 253.0 | 1303.0 | 401 | 5.15 | 172.0 | 948.0 | 303 | 5.51 | 45.0 | 74.8 | 21 | 1.66 | 44.0 | 52.5 | 15 | 1.19 | 58.0 | 118.0 | 15 | 2.03 | 71.0 | 257.0 | 74 | 3.62 | 207.0 | 1161.0 | 370 | 5.61 | 307.0 | 1707.0 | 602 | 5.56 | 372.0 | 1973.0 | 652 | 5.30 | ||||||||||||
2667 | Sole/Wasser | IDM iPump 2 - 8 | 7.9 | 2020 | 160 | 4 | 2422.3 | 11221.6 | 3608 | 4.63 | 369.6 | 1923.0 | 609 | 5.20 | 349.6 | 1586.0 | 573 | 4.54 | 310.7 | 1358.0 | 495 | 4.37 | 137.1 | 562.0 | 183 | 4.10 | 99.0 | 337.0 | 104 | 3.40 | 66.0 | 115.0 | 35 | 1.74 | 61.0 | 57.4 | 15 | 0.94 | 57.0 | 65.2 | 17 | 1.14 | 82.0 | 225.0 | 67 | 2.74 | 192.7 | 1037.0 | 335 | 5.38 | 286.6 | 1650.0 | 501 | 5.76 | 411.0 | 2306.0 | 674 | 5.61 | ||||||||||||
2667 | Sole/Wasser | IDM iPump 2 - 8 | 7.9 | 2019 | 160 | 4 | 957.9 | 3797.0 | 1148 | 3.96 | 195.7 | 610.0 | 205 | 3.12 | 359.1 | 1437.0 | 446 | 4.00 | 403.1 | 1750.0 | 497 | 4.34 |
NR | 2667 |
Username | wuschi1983 |
Einbaujahr der WP | 2019-10-01 |
PLZ des Wohnortes | 91443 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | IDM iPump 2 - 8 |
modulierend | Ja |
Leistung (0/35) | 7.9 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 60.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 29.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 160 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Im Sommer erfolgt die Kühlung mittels Passivmodul. Das Haus wird automatisch (soweit möglich) auf 23°C gehalten. Der Stromverbrauch wurde am Zählerschrank abgelesen! Dies entspricht dem tatsächlichen Stromverbrauch der WP inkl. Steuerung so wie der UWP. Grund: Die Anzeige im Navigator 2.0 ist nicht geeicht. Die angezeigten Werte müsste man in meinem Fall mit dem Faktor ~1.29 multiplizieren. PV Anlage Mitte Februar 2022 nachgerüstet: Überschuss geht in die Warmwasserbereitung mit ein (Sole + Heizstab) |