Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2669 | Luft/Wasser | IDM AERO SLM 3-11 HGL | 5.9 | 2025 | 220 | 4 | 3290.0 | 15382.0 | 2349 | 4.68 | 533.0 | 2305.0 | 409 | 4.32 | 450.0 | 1965.0 | 345 | 4.37 | 401.0 | 1909.0 | 277 | 4.76 | 261.0 | 1301.0 | 152 | 4.98 | 145.0 | 754.0 | 77 | 5.20 | 42.0 | 219.0 | 16 | 5.21 | 37.0 | 187.0 | 13 | 5.05 | 41.0 | 217.0 | 16 | 5.29 | 104.0 | 506.0 | 53 | 4.87 | 276.0 | 1444.0 | 194 | 5.23 | 438.0 | 2046.0 | 345 | 4.67 | 562.0 | 2529.0 | 452 | 4.50 | ||||||||||||
| 2669 | Luft/Wasser | IDM AERO SLM 3-11 HGL | 5.9 | 2024 | 220 | 4 | 3107.0 | 13225.0 | 1999 | 4.26 | 563.0 | 2253.0 | 391 | 4.00 | 279.0 | 1172.0 | 168 | 4.20 | 330.0 | 1285.0 | 180 | 3.89 | 328.0 | 1269.0 | 177 | 3.87 | 115.0 | 446.0 | 50 | 3.88 | 57.0 | 289.0 | 24 | 5.07 | 39.0 | 204.0 | 14 | 5.23 | 39.0 | 206.0 | 14 | 5.28 | 119.0 | 510.0 | 60 | 4.29 | 236.0 | 1102.0 | 140 | 4.67 | 420.0 | 1924.0 | 315 | 4.58 | 582.0 | 2565.0 | 466 | 4.41 | ||||||||||||
| 2669 | Luft/Wasser | IDM AERO SLM 3-11 HGL | 5.9 | 2023 | 220 | 4 | 3304.0 | 14047.0 | 2213 | 4.25 | 545.0 | 2517.0 | 454 | 4.62 | 557.0 | 2274.0 | 392 | 4.08 | 445.0 | 1815.0 | 285 | 4.08 | 372.0 | 1432.0 | 207 | 3.85 | 177.0 | 682.0 | 85 | 3.85 | 41.0 | 162.0 | 12 | 3.95 | 41.0 | 168.0 | 12 | 4.10 | 52.0 | 215.0 | 20 | 4.13 | 67.0 | 260.0 | 25 | 3.88 | 200.0 | 845.0 | 111 | 4.23 | 340.0 | 1559.0 | 253 | 4.59 | 467.0 | 2118.0 | 357 | 4.54 | ||||||||||||
| 2669 | Luft/Wasser | IDM AERO SLM 3-11 HGL | 5.9 | 2022 | 220 | 4 | 3438.0 | 14667.0 | 2230 | 4.27 | 640.0 | 3024.0 | 518 | 4.73 | 497.0 | 2148.0 | 331 | 4.32 | 481.0 | 1724.0 | 250 | 3.58 | 372.0 | 1438.0 | 201 | 3.87 | 112.0 | 416.0 | 48 | 3.71 | 44.0 | 167.0 | 16 | 3.80 | 42.0 | 158.0 | 15 | 3.76 | 38.0 | 146.0 | 14 | 3.84 | 132.0 | 509.0 | 62 | 3.86 | 149.0 | 645.0 | 74 | 4.33 | 359.0 | 1664.0 | 244 | 4.64 | 572.0 | 2628.0 | 457 | 4.59 | ||||||||||||
| 2669 | Luft/Wasser | IDM AERO SLM 3-11 HGL | 5.9 | 2021 | 220 | 2 | 3835.0 | 16681.0 | 2632 | 4.35 | 655.0 | 2800.0 | 514 | 4.27 | 561.0 | 2284.0 | 374 | 4.07 | 462.0 | 1925.0 | 312 | 4.17 | 338.0 | 1423.0 | 198 | 4.21 | 213.0 | 977.0 | 122 | 4.59 | 45.0 | 144.0 | 14 | 3.20 | 39.0 | 158.0 | 14 | 4.05 | 42.0 | 177.0 | 19 | 4.21 | 69.0 | 250.0 | 27 | 3.62 | 297.0 | 1272.0 | 174 | 4.28 | 520.0 | 2471.0 | 399 | 4.75 | 594.0 | 2800.0 | 465 | 4.71 | ||||||||||||
| 2669 | Luft/Wasser | IDM AERO SLM 3-11 HGL | 5.9 | 2020 | 220 | 2 | 868.0 | 3832.7 | 660 | 4.42 | 338.0 | 1441.0 | 242 | 4.26 | 530.0 | 2391.7 | 418 | 4.51 |
| NR | 2669 |
| Username | Buxbaum |
| Einbaujahr der WP | 2019-09-01 |
| PLZ des Wohnortes | 91710 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | IDM AERO SLM 3-11 HGL |
| modulierend | Ja |
| Leistung (0/35) | 5.9 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 0.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 220 m² |
| Lüftung | Fenster |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Neubau 2019. Einzug März 2020. Erfassung Stromverbrauch ab November 2020. Wärmepumpe mittels Solar-Log Base 15 mit PV Anlage (9,3 kwp) verbunden. IDM Hygienik 1000 l mit Frischwasserstation. Softwarefehler Wärmemengenzähler im Monat 01/21, 02/21, 03/21. |