Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2682 | DV/Wasser | M-Tec WPD618 | 10.8 | 2022 | 157 | 2 | 1800.0 | 7263.0 | 1115 | 4.04 | 500.0 | 2111.0 | 312 | 4.22 | 500.0 | 2111.0 | 313 | 4.22 | 435.0 | 1611.0 | 280 | 3.70 | 365.0 | 1430.0 | 210 | 3.92 | ||||||||||||||||||||||||||||||||||||||||||||
2682 | DV/Wasser | M-Tec WPD618 | 10.8 | 2021 | 157 | 2 | 3950.0 | 16140.0 | 2341 | 4.09 | 572.0 | 2346.0 | 367 | 4.10 | 528.0 | 2467.0 | 399 | 4.67 | 475.0 | 1840.0 | 250 | 3.87 | 475.0 | 1839.0 | 250 | 3.87 | 250.0 | 841.0 | 163 | 3.36 | 95.0 | 247.0 | 26 | 2.60 | 80.0 | 283.0 | 26 | 3.54 | 80.0 | 283.0 | 26 | 3.54 | 237.0 | 1032.0 | 126 | 4.35 | 238.0 | 1033.0 | 127 | 4.34 | 470.0 | 1917.0 | 271 | 4.08 | 450.0 | 2012.0 | 310 | 4.47 | ||||||||||||
2682 | DV/Wasser | M-Tec WPD618 | 10.8 | 2020 | 157 | 2 | 15550.0 | 72637.0 | 9734 | 4.67 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 15550.0 | 72637.0 | 9734 | 4.67 |
NR | 2682 |
Username | NewHolland |
Einbaujahr der WP | 2017-07-00 |
PLZ des Wohnortes | 15518 |
Bauart | DV/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | M-Tec WPD618 |
modulierend | Ja |
Leistung (0/35) | 10.8 kW |
berechneter Primärenergiebedarf | 32.3 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.8 m |
Fläche | 600 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 0.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 157 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Flächenkollektor selbst verlegt. Fußbodenheizung selbst verlegt. Frischwassermodul (FWM) 24 von M-TEC |