Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2727 | Luft/Wasser | Panasonic WH-MDC05H3E5 | 5.0 | 2024 | 135 | 4 | 1151.4 | 5504.0 | 4.78 | 390.7 | 1608.0 | 4.12 | 227.4 | 1237.0 | 5.44 | 220.7 | 1139.0 | 5.16 | 146.9 | 779.0 | 5.30 | 56.7 | 296.0 | 5.22 | 46.8 | 211.0 | 4.51 | 34.1 | 134.0 | 3.93 | 28.1 | 100.0 | 3.56 | |||||||||||||||||||||||||||||||||||||
2727 | Luft/Wasser | Panasonic WH-MDC05H3E5 | 5.0 | 2023 | 135 | 4 | 1900.9 | 9235.0 | 4.86 | 323.7 | 1524.0 | 4.71 | 307.8 | 1460.0 | 4.74 | 244.2 | 1213.0 | 4.97 | 204.0 | 1112.0 | 5.45 | 96.4 | 522.0 | 5.41 | 37.6 | 146.0 | 3.88 | 28.3 | 125.0 | 4.42 | 29.1 | 114.0 | 3.92 | 28.0 | 112.0 | 4.00 | 82.3 | 386.0 | 4.69 | 222.5 | 1073.0 | 4.82 | 297.0 | 1448.0 | 4.88 | |||||||||||||||||||||||||
2727 | Luft/Wasser | Panasonic WH-MDC05H3E5 | 5.0 | 2022 | 135 | 4 | 2265.2 | 10444.0 | 4.61 | 332.0 | 1600.0 | 4.82 | 296.0 | 1490.0 | 5.03 | 328.7 | 1528.0 | 4.65 | 222.0 | 1152.0 | 5.19 | 93.8 | 504.0 | 5.37 | 47.5 | 202.0 | 4.25 | 45.7 | 191.0 | 4.18 | 31.7 | 116.0 | 3.66 | 87.6 | 442.0 | 5.05 | 97.4 | 509.0 | 5.23 | 210.4 | 956.0 | 4.54 | 472.4 | 1754.0 | 3.71 | |||||||||||||||||||||||||
2727 | Luft/Wasser | Panasonic WH-MDC05H3E5 | 5.0 | 2021 | 135 | 4 | 1644.3 | 7814.0 | 4.75 | 348.0 | 1665.0 | 4.78 | 277.0 | 1412.0 | 5.10 | 138.0 | 818.0 | 5.93 | 32.7 | 113.0 | 3.46 | 31.7 | 107.0 | 3.38 | 42.0 | 141.0 | 3.36 | 40.9 | 134.0 | 3.28 | 129.0 | 625.0 | 4.84 | 239.0 | 1203.0 | 5.03 | 366.0 | 1596.0 | 4.36 |
NR | 2727 |
Username | root-2k |
Einbaujahr der WP | 2020-04-30 |
PLZ des Wohnortes | 06571 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Panasonic WH-MDC05H3E5 |
modulierend | Ja |
Leistung (0/35) | 5.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 2.0 |
Heizflaeche | 135 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | HTD Inbetriebnahme Panasonic WH-MDC05H3E5 ab 08/20 Heizkurve aktuell: 30@-15; 25@13; deltaH=2K ; kein WP-Strom Zweittarif |