Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
273 | Sole/Wasser | Nibe 1140-15 | 15.8 | 2013 | 300 | 2 | 5146.0 | 16423.0* | 953 | 3.19 | 1340.0 | 4644.0 | 276 | 3.57 | 1191.0 | 4109.0 | 244 | 3.57 | 1068.0 | 3645.0 | 215 | 3.54 | 525.0 | 1431.0 | 89 | 2.99 | 526.0 | 1431.0 | 88 | 2.99 | 247.0 | 91.0 | 20 | 0.94 | 249.0 | 92.0 | 21 | 0.93 | ||||||||||||||||||||||||||||||||
273 | Sole/Wasser | Nibe 1140-15 | 15.8 | 2012 | 300 | 2 | 6979.0 | 21644.0* | 1234 | 3.10 | 1169.0 | 3967.0 | 254 | 3.51 | 1213.0 | 4148.0 | 249 | 3.54 | 712.0 | 2134.0 | 125 | 3.19 | 528.0 | 1417.0 | 84 | 2.95 | 256.0 | 358.0 | 29 | 1.95 | 202.0 | 52.0 | 15 | 0.95 | 202.0 | 52.0 | 15 | 0.95 | 221.0 | 58.0 | 17 | 0.90 | 296.0 | 387.0 | 33 | 1.78 | 585.0 | 1982.0 | 107 | 3.63 | 585.0 | 1982.0 | 107 | 3.63 | 1010.0 | 3427.0 | 199 | 3.53 | ||||||||||||
273 | Sole/Wasser | Nibe 1140-15 | 15.8 | 2011 | 300 | 2 | 6853.0 | 20859.0* | 1368 | 3.04 | 1126.0 | 3847.0 | 246 | 3.54 | 1042.0 | 3594.0 | 229 | 3.58 | 667.0 | 2014.0 | 132 | 3.23 | 495.0 | 1236.0 | 92 | 2.78 | 328.0 | 487.0 | 58 | 1.91 | 168.0 | 42.0 | 27 | 1.08 | 168.0 | 42.0 | 27 | 1.08 | 234.0 | 8.0 | 34 | 0.63 | 252.0 | 194.0 | 40 | 1.33 | 630.0 | 1672.0 | 110 | 2.88 | 778.0 | 2681.0 | 162 | 3.63 | 965.0 | 3362.0 | 211 | 3.63 | ||||||||||||
273 | Sole/Wasser | Nibe 1140-15 | 15.8 | 2010 | 300 | 2 | 5712.0 | 21697.0* | 3.86 | 935.0 | 3649.0 | 4.05 | 655.0 | 2501.0 | 4.03 | 395.0 | 1441.0 | 4.00 | 310.0 | 1151.0 | 4.16 | 117.0 | 42.0 | 1.56 | 90.0 | 0 | 96.0 | 24.0 | 1.71 | 208.0 | 738.0 | 4.22 | 469.0 | 2031.0 | 4.63 | 868.0 | 3235.0 | 3.89 | 1569.0 | 5485.0 | 3.59 |
NR | 273 |
Username | Maxwell |
Einbaujahr der WP | 2009-11-09 |
PLZ des Wohnortes | 34281 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe 1140-15 |
modulierend | |
Leistung (0/35) | 15.8 kW |
berechneter Primärenergiebedarf | 48.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | x Erdbohrungen a |
Tiefe | 80.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 0.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 300 m² |
Lüftung | dezKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |