Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2778 | Luft/Wasser | Nibe F2120-12 | 9.0 | 2025 | 275 | 2 | 1171.8 | 4886.0 | 650 | 4.17 | 1171.8 | 4886.0 | 650 | 4.17 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2778 | Luft/Wasser | Nibe F2120-12 | 9.0 | 2024 | 275 | 2 | 4920.4 | 21572.9 | 3653 | 4.38 | 1395.2 | 4613.5 | 644 | 3.31 | 542.6 | 2716.9 | 538 | 5.01 | 378.9 | 2032.7 | 418 | 5.36 | 290.8 | 1392.2 | 264 | 4.79 | 42.5 | 204.8 | 30 | 4.82 | 12.5 | 10.0 | 2 | 0.80 | 17.3 | 32.0 | 4 | 1.85 | 17.1 | 49.0 | 8 | 2.87 | 72.6 | 336.0 | 65 | 4.63 | 316.2 | 1820.0 | 403 | 5.76 | 751.8 | 3596.3 | 629 | 4.78 | 1082.9 | 4769.5 | 648 | 4.40 | ||||||||||||
2778 | Luft/Wasser | Nibe F2120-12 | 9.0 | 2023 | 275 | 2 | 4492.6 | 20158.1 | 3623 | 4.49 | 891.4 | 3651.1 | 625 | 4.10 | 800.4 | 3387.5 | 554 | 4.23 | 606.9 | 2737.4 | 514 | 4.51 | 376.1 | 1882.8 | 383 | 5.01 | 133.2 | 698.5 | 141 | 5.24 | 12.3 | 9.7 | 1 | 0.79 | 16.8 | 35.4 | 5 | 2.11 | 34.8 | 143.9 | 23 | 4.14 | 30.3 | 107.8 | 24 | 3.56 | 213.3 | 1074.2 | 240 | 5.04 | 546.0 | 2732.4 | 502 | 5.00 | 831.1 | 3697.4 | 611 | 4.45 | ||||||||||||
2778 | Luft/Wasser | Nibe F2120-12 | 9.0 | 2022 | 275 | 2 | 4875.3 | 20077.4 | 3511 | 4.13 | 1018.5 | 4094.7 | 621 | 4.02 | 783.4 | 3487.3 | 587 | 4.45 | 669.3 | 2860.3 | 482 | 4.27 | 376.3 | 1720.8 | 348 | 4.57 | 43.0 | 197.1 | 36 | 4.58 | 18.2 | 30.1 | 8 | 1.65 | 10.9 | 13.4 | 15.2 | 2 | 1.13 | 116.1 | 583.9 | 149 | 5.03 | 109.4 | 560.0 | 155 | 5.12 | 455.5 | 2228.3 | 480 | 4.89 | 1261.3 | 4299.7 | 643 | 3.41 | |||||||||||||||
2778 | Luft/Wasser | Nibe F2120-12 | 9.0 | 2021 | 275 | 2 | 2543.7 | 11702.2 | 2044 | 4.60 | 163.4 | 1160.0 | 210 | 7.10 | 127.3 | 1052.0 | 218 | 8.26 | 19.3 | 26.2 | 3 | 1.36 | 26.0 | 90.2 | 12 | 3.47 | 44.8 | 179.6 | 24 | 4.01 | 21.3 | 64.4 | 14 | 3.02 | 380.8 | 1874.6 | 378 | 4.92 | 725.0 | 3187.0 | 555 | 4.40 | 1035.8 | 4068.2 | 630 | 3.93 |
NR | 2778 |
Username | Lindheim |
Einbaujahr der WP | 2021-04-16 |
PLZ des Wohnortes | 63674 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F2120-12 |
modulierend | Ja |
Leistung (0/35) | 9.0 kW |
berechneter Primärenergiebedarf | 90.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 44 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung |
WMZ | extern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 275 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Wärmespeicher Nibe VVM500 für Heizkreise FBH/Radiatoren u. BW, 5m2 Solarröhrenkollektor für Temp. Anhebung Wärmevorrat in der VVM500, SG ready aktiviert für Einspeisung PV Überschuss jeweils 3 Std. morgens 7-11 Uhr u. 17-21 Uhr (Vermeidung Wettbewerb mit Solarthermie) |