Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2805 | Sole/Wasser | NOVELAN SICV 6.2 K3 | 6.0 | 2023 | 121 | 3 | 987.5 | 5320.9 | 5.39 | 270.9 | 1504.8 | 5.55 | 260.7 | 1410.1 | 5.41 | 224.8 | 1274.0 | 5.67 | 132.0 | 750.8 | 5.69 | 29.7 | 113.0 | 3.80 | 23.5 | 86.7 | 3.69 | 22.8 | 90.8 | 3.98 | 23.1 | 90.7 | 3.93 | |||||||||||||||||||||||||||||||||||||
2805 | Sole/Wasser | NOVELAN SICV 6.2 K3 | 6.0 | 2022 | 121 | 3 | 1688.6 | 8936.1 | 5.29 | 313.8 | 1677.5 | 5.35 | 238.3 | 1254.4 | 5.26 | 217.0 | 1150.9 | 5.30 | 161.9 | 896.5 | 5.54 | 26.9 | 81.1 | 3.01 | 39.8 | 124.3 | 3.12 | 10.7 | 30.9 | 2.89 | 23.1 | 77.4 | 3.35 | 72.4 | 387.3 | 5.35 | 86.9 | 514.5 | 5.92 | 205.1 | 1174.6 | 5.73 | 292.7 | 1566.7 | 5.35 | |||||||||||||||||||||||||
2805 | Sole/Wasser | NOVELAN SICV 6.2 K3 | 6.0 | 2021 | 121 | 3 | 873.6 | 5022.8 | 5.75 | 17.0 | 58.0 | 3.41 | 42.9 | 210.6 | 4.91 | 71.2 | 424.4 | 5.96 | 168.7 | 1039.3 | 6.16 | 257.0 | 1572.2 | 6.12 | 316.8 | 1718.3 | 5.42 |
NR | 2805 |
Username | woban |
Einbaujahr der WP | 2021-07-09 |
PLZ des Wohnortes | 02733 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | NOVELAN SICV 6.2 K3 |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 37.6 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 100.0 m |
Fläche | 121 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung |
WMZ | intern |
Mittlere Raumtemp. | 0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 55.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 121 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |