Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2814 | Luft/Wasser | WH-MDC05J3E5 | 5.0 | 2024 | 180 | 4 | 1359.9 | 6906.0 | 1693 | 5.08 | 391.8 | 1662.0 | 409 | 4.24 | 171.3 | 987.0 | 233 | 5.76 | 160.9 | 962.0 | 239 | 5.98 | 113.1 | 632.0 | 165 | 5.59 | 45.5 | 218.0 | 48 | 4.79 | 28.9 | 117.1 | 20 | 4.05 | 30.3 | 130.9 | 20 | 4.32 | 27.1 | 112.0 | 17 | 4.13 | 48.2 | 229.0 | 57 | 4.75 | 108.5 | 629.0 | 183 | 5.80 | 234.3 | 1227.0 | 302 | 5.24 | ||||||||||||||||
2814 | Luft/Wasser | WH-MDC05J3E5 | 5.0 | 2023 | 180 | 3 | 1989.6 | 9463.0 | 2401 | 4.76 | 388.6 | 1736.0 | 453 | 4.47 | 367.7 | 1656.0 | 425 | 4.50 | 275.8 | 1407.0 | 343 | 5.10 | 98.5 | 490.0 | 137 | 4.97 | 75.3 | 402.0 | 101 | 5.34 | 33.4 | 125.0 | 21 | 3.74 | 33.1 | 116.0 | 21 | 3.50 | 33.2 | 117.0 | 22 | 3.52 | 32.6 | 117.0 | 19 | 3.59 | 118.0 | 661.0 | 188 | 5.60 | 232.9 | 1195.0 | 304 | 5.13 | 300.5 | 1441.0 | 367 | 4.80 | ||||||||||||
2814 | Luft/Wasser | WH-MDC05J3E5 | 5.0 | 2022 | 180 | 3 | 2123.3 | 10061.0 | 2491 | 4.74 | 384.0 | 1719.0 | 431 | 4.48 | 273.0 | 1348.0 | 360 | 4.94 | 290.6 | 1443.0 | 393 | 4.97 | 191.1 | 1036.0 | 247 | 5.42 | 49.3 | 207.0 | 45 | 4.20 | 28.9 | 106.0 | 18 | 3.67 | 26.8 | 96.0 | 16 | 3.58 | 21.9 | 74.0 | 12 | 3.38 | 58.8 | 314.0 | 68 | 5.34 | 96.5 | 596.0 | 146 | 6.18 | 227.6 | 1208.0 | 283 | 5.31 | 474.8 | 1914.0 | 472 | 4.03 | ||||||||||||
2814 | Luft/Wasser | WH-MDC05J3E5 | 5.0 | 2021 | 180 | 1267.8 | 6662.0 | 1579 | 5.25 | 352.2 | 2150.0 | 580 | 6.10 | 260.6 | 1497.0 | 277 | 5.74 | 304.0 | 1339.0 | 328 | 4.40 | 351.0 | 1676.0 | 394 | 4.77 |
NR | 2814 |
Username | asako |
Einbaujahr der WP | 2021-09-01 |
PLZ des Wohnortes | 97776 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | WH-MDC05J3E5 |
modulierend | Ja |
Leistung (0/35) | 5.0 kW |
berechneter Primärenergiebedarf | 50.9 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 20 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 29.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 180 m² |
Lüftung | zenKWL |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Heisha als alleinige Wärmequelle. CAF Estrich Trocknung ab 10.09.2021. Heizlastberechnung durch SkyMe. Gesamtfläche ~180m² auch mit FBH, davon Wohnfläche 140m² |