Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2843 | Sole/Wasser | Nibe S1255-6 OC | 6.0 | 2023 | 205 | 4 | 1586.0 | 8039.0 | 5.07 | 363.0 | 2023.0 | 5.57 | 395.0 | 1930.0 | 4.89 | 359.0 | 1768.0 | 4.92 | 269.0 | 1352.0 | 5.03 | 115.0 | 571.0 | 4.97 | 44.0 | 196.0 | 4.45 | 41.0 | 199.0 | 4.85 | ||||||||||||||||||||||||||||||||||||||||
2843 | Sole/Wasser | Nibe S1255-6 OC | 6.0 | 2022 | 205 | 3 | 2130.0 | 12995.0 | 6.10 | 385.0 | 2192.0 | 5.69 | 340.0 | 1931.0 | 5.68 | 305.0 | 1690.0 | 5.54 | 204.0 | 1091.0 | 5.35 | 47.0 | 352.0 | 7.49 | 34.0 | 299.0 | 8.79 | 28.0 | 327.0 | 11.68 | 25.0 | 277.0 | 11.08 | 75.0 | 552.0 | 7.36 | 94.0 | 679.0 | 7.22 | 243.0 | 1592.0 | 6.55 | 350.0 | 2013.0 | 5.75 | |||||||||||||||||||||||||
2843 | Sole/Wasser | Nibe S1255-6 OC | 6.0 | 2021 | 205 | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2843 | Sole/Wasser | Nibe S1255-6 OC | 6.0 | 2021 | 205 | 3 | 1409.0 | 5962.0 | 1587 | 4.23 | 1409.0 | 5962.0 | 1587 | 4.23 |
NR | 2843 |
Username | Larox |
Einbaujahr der WP | 2021-10-15 |
PLZ des Wohnortes | 93491 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe S1255-6 OC |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.8 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: Kompressor |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 6.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 205 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |