Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2844 | Luft/Wasser | Panasonic WH-MDC05J3E5 | 5.0 | 2024 | 135 | 3 | 1355.0 | 5351.0 | 1556 | 3.95 | 517.0 | 1877.0 | 600 | 3.63 | 278.0 | 1176.0 | 358 | 4.23 | 284.0 | 1218.0 | 351 | 4.29 | 155.0 | 647.0 | 166 | 4.17 | 56.0 | 198.0 | 37 | 3.54 | 33.0 | 119.0 | 23 | 3.61 | 32.0 | 116.0 | 21 | 3.63 | ||||||||||||||||||||||||||||||||
2844 | Luft/Wasser | Panasonic WH-MDC05J3E5 | 5.0 | 2023 | 135 | 3 | 2395.0 | 9487.0 | 2854 | 3.96 | 427.0 | 1648.0 | 509 | 3.86 | 382.0 | 1537.0 | 511 | 4.02 | 324.0 | 1282.0 | 413 | 3.96 | 209.0 | 888.0 | 261 | 4.25 | 65.0 | 252.0 | 53 | 3.88 | 33.0 | 133.0 | 23 | 4.03 | 37.0 | 107.0 | 19 | 2.89 | 49.0 | 162.0 | 29 | 3.31 | 29.0 | 97.0 | 18 | 3.34 | 149.0 | 656.0 | 165 | 4.40 | 332.0 | 1252.0 | 400 | 3.77 | 359.0 | 1473.0 | 453 | 4.10 | ||||||||||||
2844 | Luft/Wasser | Panasonic WH-MDC05J3E5 | 5.0 | 2022 | 135 | 3 | 2256.3 | 8734.0 | 2494 | 3.87 | 420.0 | 1646.0 | 501 | 3.92 | 340.0 | 1436.0 | 441 | 4.22 | 301.0 | 1204.0 | 380 | 4.00 | 167.5 | 690.0 | 198 | 4.12 | 60.3 | 234.0 | 47 | 3.88 | 43.2 | 165.0 | 29 | 3.82 | 33.0 | 116.0 | 24 | 3.52 | 34.0 | 132.0 | 21 | 3.88 | 49.0 | 160.0 | 32 | 3.27 | 49.3 | 175.0 | 42 | 3.55 | 264.0 | 1030.0 | 235 | 3.90 | 495.0 | 1746.0 | 544 | 3.53 | ||||||||||||
2844 | Luft/Wasser | Panasonic WH-MDC05J3E5 | 5.0 | 2021 | 135 | 3 | 960.0 | 3781.0 | 553 | 3.94 | 15.0 | 50.0 | 3.33 | 27.0 | 72.0 | 2.67 | 40.0 | 133.0 | 3.33 | 132.0 | 603.0 | 4.57 | 296.0 | 1222.0 | 4.13 | 450.0 | 1701.0 | 553 | 3.78 |
NR | 2844 |
Username | Tenket |
Einbaujahr der WP | 2021-06-21 |
PLZ des Wohnortes | 30926 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Panasonic WH-MDC05J3E5 |
modulierend | Ja |
Leistung (0/35) | 5.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 34 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 45.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 135 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | KFW60 9kWP PV vorher Gasheiz. 10.000 kWh/a, Radiator Typ33 in WZ, ohne Pufferspeicher |