Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2858 | Sole/Wasser | Junkers STE60-1 | 5.8 | 2024 | 95 | 2 | 739.0 | 3618.0 | 557 | 4.90 | 272.0 | 1333.0 | 205 | 4.90 | 196.0 | 950.0 | 146 | 4.85 | 160.0 | 782.0 | 119 | 4.89 | 101.0 | 512.0 | 75 | 5.07 | 10.0 | 41.0 | 12 | 4.10 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||||||||
2858 | Sole/Wasser | Junkers STE60-1 | 5.8 | 2023 | 95 | 1 | 1220.0 | 6228.0 | 940 | 5.10 | 216.0 | 1090.0 | 164 | 5.05 | 196.0 | 963.0 | 150 | 4.91 | 176.0 | 853.0 | 134 | 4.85 | 133.0 | 663.0 | 101 | 4.98 | 40.0 | 189.0 | 48 | 4.73 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 67.0 | 385.0 | 48 | 5.75 | 162.0 | 894.0 | 121 | 5.52 | 230.0 | 1191.0 | 174 | 5.18 | ||||||||||||||||||
2858 | Sole/Wasser | Junkers STE60-1 | 5.8 | 2022 | 95 | 1 | 1013.5 | 5055.0 | 749 | 4.99 | 217.0 | 1055.0 | 158 | 4.86 | 171.0 | 822.0 | 127 | 4.81 | 113.0 | 557.0 | 86 | 4.93 | 98.0 | 481.0 | 70 | 4.91 | 15.0 | 47.0 | 15 | 3.13 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 4.5 | 22.0 | 2 | 4.89 | 25.0 | 116.0 | 15 | 4.64 | 128.0 | 714.0 | 95 | 5.58 | 242.0 | 1241.0 | 181 | 5.13 | |||||||||||||||
2858 | Sole/Wasser | Junkers STE60-1 | 5.8 | 2021 | 95 | 1 | 401.0 | 1985.0 | 386 | 4.95 | 51.0 | 196.0 | 24 | 3.84 | 126.0 | 645.0 | 86 | 5.12 | 224.0 | 1144.0 | 276 | 5.11 |
NR | 2858 |
Username | Nordfjord |
Einbaujahr der WP | 2021-10-01 |
PLZ des Wohnortes | 17109 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Junkers STE60-1 |
modulierend | Nein |
Leistung (0/35) | 5.8 kW |
berechneter Primärenergiebedarf | 62.0 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 0 °C |
WW Legionellenschaltung | |
WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.5 m |
Fläche | 500 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 95 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | keine ERR, kein Puffer, Kollektor ohne Glykol (reines Wasser). Warmwasser über Durchlauferhitzer. |