Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2859 | Luft/Wasser | Mitsubishi PUHZ-SHW11 | 11.0 | 2025 | 180 | 5 | 3993.5 | 12682.0 | 790 | 3.18 | 702.2 | 2068.0 | 95 | 2.95 | 653.4 | 1944.0 | 86 | 2.98 | 574.9 | 1899.0 | 75 | 3.30 | 356.9 | 1218.0 | 61 | 3.41 | 290.3 | 1010.0 | 106 | 3.48 | 80.5 | 222.0 | 4 | 2.76 | 100.0 | 297.0 | 27 | 2.97 | 91.4 | 268.0 | 40 | 2.93 | 153.8 | 552.0 | 40 | 3.59 | 387.4 | 1383.0 | 82 | 3.57 | 503.0 | 1529.0 | 133 | 3.04 | 99.7 | 292.0 | 41 | 2.93 | ||||||||||||
| 2859 | Luft/Wasser | Mitsubishi PUHZ-SHW11 | 11.0 | 2024 | 180 | 5 | 3225.4 | 10318.0 | 2437 | 3.20 | 487.5 | 1465.0 | 180 | 3.01 | 500.0 | 1758.0 | 219 | 3.52 | 212 | 416.8 | 1360.0 | 132 | 3.26 | 195.5 | 669.0 | 77 | 3.42 | 32.0 | 42.0 | 5 | 1.31 | 35.6 | 57.0 | 420 | 1.60 | 40.0 | 66.0 | 5 | 1.65 | 165.2 | 555.0 | 429 | 3.36 | 264.3 | 1019.0 | 51 | 3.86 | 560.7 | 1764.0 | 537 | 3.15 | 527.8 | 1563.0 | 170 | 2.96 | |||||||||||||||
| 2859 | Luft/Wasser | Mitsubishi PUHZ-SHW11 | 11.0 | 2023 | 180 | 5 | 3593.7 | 11201.0 | 1491 | 3.12 | 468.4 | 1431.0 | 189 | 3.06 | 616.7 | 1772.0 | 254 | 2.87 | 610.8 | 1893.0 | 276 | 3.10 | 529.1 | 1696.0 | 228 | 3.21 | 227.3 | 820.0 | 98 | 3.61 | 49.8 | 107.0 | 11 | 2.15 | 58.7 | 140.0 | 15 | 2.39 | 83.9 | 281.0 | 24 | 3.35 | 88.0 | 246.0 | 29 | 2.80 | 236.4 | 825.0 | 112 | 3.49 | 232.9 | 711.0 | 93 | 3.05 | 391.7 | 1279.0 | 162 | 3.27 | ||||||||||||
| 2859 | Luft/Wasser | Mitsubishi PUHZ-SHW11 | 11.0 | 2022 | 180 | 5 | 1604.3 | 5136.0 | 579 | 3.20 | 150.0 | 451.0 | 3.01 | 137.5 | 443.0 | 3.22 | 122.8 | 378.0 | 46 | 3.08 | 97.3 | 276.0 | 30 | 2.84 | 193.4 | 630.0 | 84 | 3.26 | 244.3 | 925.0 | 127 | 3.79 | 326.4 | 1033.0 | 156 | 3.16 | 332.6 | 1000.0 | 136 | 3.01 |
| NR | 2859 |
| Username | ds1707 |
| Einbaujahr der WP | 2022-03-01 |
| PLZ des Wohnortes | 87487 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Bi |
| Hersteller Typ | Mitsubishi PUHZ-SHW11 |
| modulierend | Ja |
| Leistung (0/35) | 11.0 kW |
| berechneter Primärenergiebedarf | 70.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 55 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 21 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung |
| WMZ | extern_geeicht |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 0.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 180 m² |
| Lüftung | dezKWLWR |
| Personen | 5 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Wärmepumpenstrom mit Standby-Stromverbrauch ohne Pumpenstrom. PVHeiz mit Eigenverbauchsoptimierung deshalb geringerer cop aber höherer Eigenverbrauch. |