Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2874 | Sole/Wasser | Weishaupt ID6 | 6.1 | 2025 | 140 | 2 | 386.0 | 1575.0 | 280 | 4.08 | 386.0 | 1575.0 | 280 | 4.08 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2874 | Sole/Wasser | Weishaupt ID6 | 6.1 | 2024 | 140 | 2 | 1432.0 | 6442.0 | 984 | 4.50 | 355.0 | 1464.0 | 260 | 4.12 | 290.0 | 1464.0 | 162 | 5.05 | 75.0 | 375.0 | 58 | 5.00 | 77.0 | 396.0 | 58 | 5.14 | 47.0 | 40.0 | 5 | 0.85 | 77.0 | 401.0 | 59 | 5.21 | 214.0 | 1006.0 | 162 | 4.70 | 297.0 | 1296.0 | 220 | 4.36 | ||||||||||||||||||||||||||||
2874 | Sole/Wasser | Weishaupt ID6 | 6.1 | 2023 | 140 | 2 | 1306.0 | 6895.0 | 1023 | 5.28 | 303.0 | 1622.0 | 230 | 5.35 | 218.0 | 1195.0 | 167 | 5.48 | 157.0 | 890.0 | 122 | 5.67 | 115.0 | 691.0 | 93 | 6.01 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 46.0 | 248.0 | 37 | 5.39 | 203.0 | 958.0 | 155 | 4.72 | 264.0 | 1291.0 | 219 | 4.89 | |||||||||||||||||
2874 | Sole/Wasser | Weishaupt ID6 | 6.1 | 2022 | 140 | 2 | 1569.0 | 8047.0 | 1150 | 5.13 | 419.0 | 2036.0 | 306 | 4.86 | 335.0 | 1684.0 | 243 | 5.03 | 199.0 | 1071.0 | 149 | 5.38 | 120.0 | 650.0 | 89 | 5.42 | 24.0 | 131.0 | 4 | 5.46 | 128.0 | 665.0 | 100 | 5.20 | 344.0 | 1810.0 | 259 | 5.26 | ||||||||||||||||||||||||||||||||
2874 | Sole/Wasser | Weishaupt ID6 | 6.1 | 2021 | 140 | 2 | 1930.0 | 9825.0 | 1444 | 5.09 | 373.0 | 1991.0 | 284 | 5.34 | 260.0 | 1395.0 | 203 | 5.37 | 214.0 | 1204.0 | 166 | 5.63 | 158.0 | 884.0 | 121 | 5.59 | 71.0 | 425.0 | 55 | 5.99 | 108.0 | 620.0 | 80 | 5.74 | 314.0 | 1612.0 | 223 | 5.13 | 432.0 | 1694.0 | 312 | 3.92 |
NR | 2874 |
Username | jaz |
Einbaujahr der WP | 2020-11-15 |
PLZ des Wohnortes | 52525 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Weishaupt ID6 |
modulierend | Nein |
Leistung (0/35) | 6.1 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 100.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 1600 Watt DB |
elektr. Verbrauch HP gem./DB | 80 Watt |
elektr. Verbrauch WQ P gem./DB | 20 Watt |
Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 7.5 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 140 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Warmwasser mit Solarunterstützung Altbau Bj 1991 |