Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2913 | Luft/Wasser | IDM AERO SLM 6-17 HGL | 11.3 | 2025 | 160 | 3 | 590.0 | 2561.0 | 323 | 4.34 | 590.0 | 2561.0 | 323 | 4.34 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2913 | Luft/Wasser | IDM AERO SLM 6-17 HGL | 11.3 | 2024 | 160 | 3 | 2539.1 | 11735.0 | 1583 | 4.62 | 634.0 | 2685.0 | 394 | 4.24 | 270.0 | 1515.0 | 225 | 5.61 | 296.0 | 1640.0 | 235 | 5.54 | 84.1 | 375.0 | 43 | 4.46 | 58.0 | 253.0 | 23 | 4.36 | 43.0 | 191.0 | 17 | 4.44 | 46.0 | 216.0 | 19 | 4.70 | 39.0 | 186.0 | 16 | 4.77 | 55.0 | 222.0 | 22 | 4.04 | 68.0 | 250.0 | 27 | 3.68 | 344.0 | 1621.0 | 224 | 4.71 | 602.0 | 2581.0 | 338 | 4.29 | ||||||||||||
2913 | Luft/Wasser | IDM AERO SLM 6-17 HGL | 11.3 | 2023 | 160 | 3 | 2140.4 | 9754.0 | 1290 | 4.56 | 433.0 | 1907.0 | 280 | 4.40 | 454.0 | 2001.0 | 283 | 4.41 | 272.0 | 1243.0 | 155 | 4.57 | 64.7 | 258.0 | 26 | 3.99 | 61.0 | 269.0 | 25 | 4.41 | 51.0 | 252.0 | 22 | 4.94 | 39.3 | 190.0 | 19 | 4.83 | 43.0 | 203.0 | 17 | 4.72 | 50.4 | 233.0 | 20 | 4.62 | 58.0 | 243.0 | 23 | 4.19 | 204.0 | 937.0 | 129 | 4.59 | 410.0 | 2018.0 | 291 | 4.92 | ||||||||||||
2913 | Luft/Wasser | IDM AERO SLM 6-17 HGL | 11.3 | 2022 | 160 | 3 | 2718.0 | 12260.0 | 1955 | 4.51 | 845.0 | 3669.0 | 679 | 4.34 | 571.0 | 2714.0 | 483 | 4.75 | 161.0 | 677.0 | 85 | 4.20 | 107.0 | 447.0 | 63 | 4.18 | 52.0 | 249.0 | 21 | 4.79 | 43.0 | 218.0 | 17 | 5.07 | 37.0 | 190.0 | 15 | 5.14 | 42.0 | 216.0 | 17 | 5.14 | 53.0 | 234.0 | 21 | 4.42 | 53.0 | 237.0 | 21 | 4.47 | 233.0 | 1195.0 | 203 | 5.13 | 521.0 | 2214.0 | 330 | 4.25 | ||||||||||||
2913 | Luft/Wasser | IDM AERO SLM 6-17 HGL | 11.3 | 2021 | 160 | 3 | 1264.0 | 5493.0 | 980 | 4.35 | 481.0 | 2043.0 | 342 | 4.25 | 783.0 | 3450.0 | 638 | 4.41 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
2913 | Luft/Wasser | IDM AERO SLM 6-17 HGL | 11.3 | 160 |
NR | 2913 |
Username | Volldruff |
Einbaujahr der WP | 2021-10-20 |
PLZ des Wohnortes | 74632 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | IDM AERO SLM 6-17 HGL |
modulierend | Ja |
Leistung (0/35) | 11.3 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 52 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 12 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: Kompressor |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 38.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 160 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | 800 Liter Hygienespeicher von Sonnenkraft SOTPC 800 Strom und Wärmemenge sind vom Navigator 2.0 |