Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2972 | Luft/Wasser | Vaillant Arotherm plus 75/6 | 7.0 | 2025 | 212 | 4 | 4151.0 | 15603.0 | 3.76 | 764.0 | 2360.0 | 3.09 | 572.0 | 2211.0 | 3.87 | 444.0 | 1811.0 | 4.08 | 229.0 | 835.0 | 3.65 | 113.0 | 307.0 | 2.72 | 173.0 | 703.0 | 4.06 | 100.0 | 365.0 | 3.65 | 135.0 | 470.0 | 3.48 | 115.0 | 408.0 | 3.55 | 303.0 | 1353.0 | 4.47 | 535.0 | 2137.0 | 3.99 | 668.0 | 2643.0 | 3.96 | |||||||||||||||||||||||||
| 2972 | Luft/Wasser | Vaillant Arotherm plus 75/6 | 7.0 | 2024 | 212 | 4 | 3249.3 | 14125.0 | 4.35 | 682.0 | 3349.0 | 4.91 | 340.0 | 2111.0 | 6.21 | 311.7 | 1740.0 | 5.58 | 159.6 | 822.0 | 5.15 | 118.0 | 581.0 | 4.92 | 85.0 | 240.0 | 2.82 | 75.0 | 211.0 | 2.81 | 72.0 | 201.0 | 2.79 | 120.0 | 416.0 | 3.47 | 198.0 | 745.0 | 3.76 | 470.0 | 1683.0 | 3.58 | 618.0 | 2026.0 | 3.28 | |||||||||||||||||||||||||
| 2972 | Luft/Wasser | Vaillant Arotherm plus 75/6 | 7.0 | 2023 | 212 | 4 | 3237.0 | 17686.5 | 5.46 | 557.0 | 3151.0 | 5.66 | 483.0 | 2556.0 | 5.29 | 385.0 | 2129.0 | 5.53 | 314.0 | 1730.0 | 5.51 | 127.0 | 594.0 | 4.68 | 74.0 | 335.0 | 4.53 | 68.0 | 302.0 | 4.44 | 64.0 | 285.0 | 4.45 | 68.0 | 285.0 | 4.19 | 163.0 | 955.5 | 5.86 | 376.5 | 2339.0 | 6.21 | 557.5 | 3025.0 | 5.43 | |||||||||||||||||||||||||
| 2972 | Luft/Wasser | Vaillant Arotherm plus 75/6 | 7.0 | 2022 | 212 | 3 | 3401.0 | 18583.0 | 5.46 | 669.0 | 3486.0 | 5.21 | 432.0 | 2532.0 | 5.86 | 401.0 | 2277.0 | 5.68 | 311.0 | 1812.0 | 5.83 | 90.0 | 423.0 | 4.70 | 81.0 | 381.0 | 4.70 | 71.0 | 336.0 | 4.73 | 77.0 | 361.0 | 4.69 | 110.0 | 598.0 | 5.44 | 181.0 | 1066.0 | 5.89 | 328.0 | 1927.0 | 5.88 | 650.0 | 3384.0 | 5.21 | |||||||||||||||||||||||||
| 2972 | Luft/Wasser | Vaillant Arotherm plus 75/6 | 7.0 | 2021 | 212 | 3 | 1402.0 | 7851.0 | 5.60 | 298.0 | 1797.0 | 6.03 | 510.0 | 2915.0 | 5.72 | 594.0 | 3139.0 | 5.28 |
| NR | 2972 |
| Username | BillMurray |
| Einbaujahr der WP | 2021-10-15 |
| PLZ des Wohnortes | 84453 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Bi |
| Hersteller Typ | Vaillant Arotherm plus 75/6 |
| modulierend | Ja |
| Leistung (0/35) | 7.0 kW |
| berechneter Primärenergiebedarf | 14.5 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 49 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 32.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 212 m² |
| Lüftung | zenKWLWR |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Holz Fachwerkhaus im KFW 55 Standard gebaut. Oktober 2021 Fertigstellung. Extrem viele Glasflächen |