Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2972 | Luft/Wasser | Vaillant Arotherm plus 75/6 | 7.0 | 2024 | 212 | 4 | 1696.3 | 8843.0 | 5.21 | 682.0 | 3349.0 | 4.91 | 340.0 | 2111.0 | 6.21 | 311.7 | 1740.0 | 5.58 | 159.6 | 822.0 | 5.15 | 118.0 | 581.0 | 4.92 | 85.0 | 240.0 | 2.82 | |||||||||||||||||||||||||||||||||||||||||||
2972 | Luft/Wasser | Vaillant Arotherm plus 75/6 | 7.0 | 2023 | 212 | 4 | 3237.0 | 17686.5 | 5.46 | 557.0 | 3151.0 | 5.66 | 483.0 | 2556.0 | 5.29 | 385.0 | 2129.0 | 5.53 | 314.0 | 1730.0 | 5.51 | 127.0 | 594.0 | 4.68 | 74.0 | 335.0 | 4.53 | 68.0 | 302.0 | 4.44 | 64.0 | 285.0 | 4.45 | 68.0 | 285.0 | 4.19 | 163.0 | 955.5 | 5.86 | 376.5 | 2339.0 | 6.21 | 557.5 | 3025.0 | 5.43 | |||||||||||||||||||||||||
2972 | Luft/Wasser | Vaillant Arotherm plus 75/6 | 7.0 | 2022 | 212 | 3 | 3401.0 | 18583.0 | 5.46 | 669.0 | 3486.0 | 5.21 | 432.0 | 2532.0 | 5.86 | 401.0 | 2277.0 | 5.68 | 311.0 | 1812.0 | 5.83 | 90.0 | 423.0 | 4.70 | 81.0 | 381.0 | 4.70 | 71.0 | 336.0 | 4.73 | 77.0 | 361.0 | 4.69 | 110.0 | 598.0 | 5.44 | 181.0 | 1066.0 | 5.89 | 328.0 | 1927.0 | 5.88 | 650.0 | 3384.0 | 5.21 | |||||||||||||||||||||||||
2972 | Luft/Wasser | Vaillant Arotherm plus 75/6 | 7.0 | 2021 | 212 | 3 | 1402.0 | 7851.0 | 5.60 | 298.0 | 1797.0 | 6.03 | 510.0 | 2915.0 | 5.72 | 594.0 | 3139.0 | 5.28 |
NR | 2972 |
Username | BillMurray |
Einbaujahr der WP | 2021-10-15 |
PLZ des Wohnortes | 84453 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Vaillant Arotherm plus 75/6 |
modulierend | Ja |
Leistung (0/35) | 7.0 kW |
berechneter Primärenergiebedarf | 14.5 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 49 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 212 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |